23
4
NOTE
• "Analog output" means the voltage (0 to
10 V) and current (0 to 20 mA) output from terminals AM0 and AM1; while
"output signal" indicates the monitor signal (refer to
) set in parameters
Pr.306
and
Pr.310
.
1
Outputs separate selection signals from the
voltage output terminal (AM0) and the current
output terminal (AM1).
AM0
Pr.310
:
Pr.311
:
Pr.312
:
Selects the output signal.
Output signal value when analog
output is zero.
Output signal value when analog
output is at maximum.
Pr.323
C0 (Pr.900)
AM1
Pr.306
:
Pr.307
:
Pr.308
:
Selects the output signal.
Output signal value when analog
output is zero.
Output signal value when analog
output is at maximum.
Pr.324
C1 (Pr.901)
11
AM0
Pr.310
:
Pr.311
:
Pr.312
:
Selects the output signal.
Analog output value when output
signal is zero.
Analog output value when output
signal is at maximum.
Pr.323
C0 (Pr.900)
AM1
Pr.306
:
Pr.307
:
Pr.308
:
Selects the output signal.
Analog output value when output
signal is zero.
Analog output value when output
signal is at maximum.
Pr.324
C1 (Pr.901)
Pr.309
setting
value
Parameter setting
Calibration
parameter
Description
Terminal