58
7.4
Emergency object
This object is used for reporting an inverter error from the slave to the master.
<model>
<request format>
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Byte0
Emergency Error Code(L)
Byte1
Emergency Error Code(H)
Byte2
Error Register (same description as Index1001h)
Byte3
blank(0)
Byte4
blank(0)
Byte5
blank(0)
Byte6
blank(0)
Byte7
blank(0)
request
Indication
Indication
Indication
EMCY Producer
EMCY Consumer
Write EMCY
Emergency Object Data
0