21
EXTENSION ANALOG OUTPUT
4
4.5.3 Output signal setting
Set the output signals to be monitored. Set
Pr. 306
to output the same signal from terminals AM0 and AM1
and
Pr. 306
and
Pr. 310
to output different signals. For details of signal definitions, refer to
Pr. 54 and Pr. 158
of
the inverter instruction manual.
Pr. 306/Pr. 310
Setting
Types of Monitor
Increments
Full-Scale Value
1
Output frequency
0.01Hz
Pr. 55
2
Output current
0.01A
Pr. 56
3
Output voltage
0.1V
200V class : 400V
400V class : 800V
5
Frequency setting
0.01Hz
Pr. 55
7
Motor torque
0.1%
Rated torque of the applied motor
×
2
8
Converter output voltage
0.1V
200V class : 400V
400V class : 800V
9
Regenerative brake duty
0.1%
Pr. 70
10
Electronic thermal relay function load factor
0.1%
100%
11
Output current peak value
0.01
Pr. 56
12
Converter output voltage peak value
0.1V
200V class : 400V
400V class : 800V
14
Output power
0.01kW
Rated inverter power
×
2
21
Reference voltage output
⎯
⎯
24
Motor load factor
0.1%
200%
52
PID set point
0.1%
100%
53
PID process value
0.1%
100%
61
Motor thermal load factor
0.1%
Thermal relay operation level (100%)
62
Inverter thermal load factor
0.1%
Thermal relay operation level (100%)