15
PARAMETER LIST
139
Automatic switchover
frequency from inverter to
bypass operation
0 to 60Hz,
9999
9999
140
Backlash acceleration
stopping frequency
0 to 400Hz
1Hz
141
Backlash acceleration
stopping time
0 to 360s
0.5s
142
Backlash deceleration
stopping frequency
0 to 400Hz
1Hz
143
Backlash deceleration
stopping time
0 to 360s
0.5s
144
Speed setting switchover
0, 2, 4, 6, 8,
10, 102, 104,
106, 108, 110
4
145
PU display language
selection
0 to 7
1
148
Stall prevention level at 0V
input
0 to 220%
150%
149
Stall prevention level at 10V
input
0 to 220%
200%
150
Output current detection
level
0 to 220%
150%
151
Output current detection
signal delay time
0 to 10s
0s
152
Zero current detection level
0 to 220%
5%
153
Zero current detection time
0 to 1s
0.5s
154
Voltage reduction selection
during stall prevention
operation
0, 1
1
155
RT signal function validity
condition selection
0, 10
0
156
Stall prevention operation
selection
0 to 31, 100,
101
0
157
OL signal output timer
0 to 25s, 9999
0s
158
AM terminal function
selection
1 to 3, 5 to 14,
17, 18, 21, 24,
32 to 34, 50,
52, 53, 70
1
159
Automatic switchover
frequency range from
bypass to inverter operation
0 to 10Hz,
9999
9999
160
User group read selection
0, 1, 9999
0
161
Frequency setting/key lock
operation selection
0, 1, 10, 11
0
162
Automatic restart after
instantaneous power failure
selection
0, 1, 2, 10, 11,
12
0
163
First cushion time for restart
0 to 20s
0s
164
First cushion voltage for
restart
0 to 100%
0%
165
Stall prevention operation
level for restart
0 to 220%
150%
166
Output current detection
signal retention time
0 to 10s, 9999
0.1s
167
Output current detection
operation selection
0, 1
0
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0, 10, 9999
9999
171
Operation hour meter clear
0, 9999
9999
Parameter
Name
Setting
Range
Initial
Value
172
User group registered
display/batch clear
9999, (0 to 16)
0
173
User group registration
0 to 999, 9999
9999
174
User group clear
0 to 999, 9999
9999
178
STF terminal function
selection
0 to 20, 22 to
28, 42 to 44,
50, 60, 62, 64
to 71, 74, 9999
60
179
STR terminal function
selection
0 to 20, 22 to
28, 42 to 44,
50, 61, 62, 64
to 71, 74, 9999
61
180
RL terminal function
selection
0 to 20, 22 to
28, 42 to 44,
50, 62, 64 to
71, 74, 9999
0
181
RM terminal function
selection
1
182
RH terminal function
selection
2
183
RT terminal function
selection
3
184
AU terminal function
selection
0 to 20, 22 to
28, 42 to 44,
50, 62 to 71,
74, 9999
4
185
JOG terminal function
selection
0 to 20, 22 to
28, 42 to 44,
50, 62, 64 to
71, 74, 9999
5
186
CS terminal function
selection
6
187
MRS terminal function
selection
24
188
STOP terminal function
selection
25
189
RES terminal function
selection
62
190
RUN terminal function
selection
0 to 8, 10 to
20, 25 to 28,
30 to 36, 39,
41 to 47, 64,
70, 84, 85, 90
to 99,
100 to 108,
110 to 116,
120, 125 to
128, 130 to
136, 139, 141
to 147, 164,
170, 184, 185,
190 to 199,
9999
0
191
SU terminal function
selection
1
192
IPF terminal function
selection
2
193
OL terminal function
selection
3
194
FU terminal function
selection
4
195
ABC1 terminal function
selection
0 to 8, 10 to
20, 25 to 28,
30 to 36, 39,
41 to 47, 64,
70, 84, 85, 90,
91, 94 to 99,
100 to 108,
110 to 116,
120, 125 to
128, 130 to
136, 139, 141
to 147, 164,
170, 184, 185,
190, 191, 194
to 199, 9999
99
196
ABC2 terminal function
selection
9999
232 to
239
Multi-speed setting (8 speed
to 15 speed)
0 to 400Hz,
9999
9999
240
Soft-PWM operation
selection
0, 1
1
241
Analog input display unit
switchover
0, 1
0