14
PARAMETER
119
PU communication
stop bit length
0, 1, 10, 11
1
120
PU communication
parity check
0, 1, 2
2
121
Number of PU
communication retries
0 to 10, 9999
1
122
PU communication
check time interval
0, 0.1 to 999.8s,
9999
9999
123
PU communication
waiting time setting
0 to 150ms,
9999
9999
124
PU communication
CR/LF selection
0, 1, 2
1
125
Terminal 2 frequency
setting gain frequency
0 to 400Hz
60Hz
126
Terminal 4 frequency
setting gain frequency
0 to 400Hz
60Hz
127
PID operation
PID control auto-
matic switcho-
ver frequency
0 to 400Hz,
9999
9999
128
PID action selec-
tion
10, 11, 20, 21,
50, 51, 60, 61
10
129
PID proportional
band
0.1 to 1000%,
9999
100%
130
PID integral time
0.1 to 3600s,
9999
1s
131
PID upper limit
0 to 100%, 9999
9999
132
PID lower limit
0 to 100%, 9999
9999
133
PID action set
point
0 to 100%, 9999
9999
134
PID differential
time
0.01 to 10.00s,
9999
9999
135
Byp
a
ss
Electronic
bypass sequence
selection
0, 1
0
136
MC switchover
interlock time
0 to 100s
1s
137
Start waiting time
0 to 100s
0.5s
138
Bypass selec-
tion at a fault
0, 1
0
139
Automatic
switchover
frequency from
inverter to
bypass operation
0 to 60Hz, 9999
9999
140
Backlash measures
Backlash accel-
eration stopping
frequency
0 to 400Hz
1Hz
141
Backlash accel-
eration stopping
time
0 to 360s
0.5s
142
Backlash
deceleration
stopping
frequency
0 to 400Hz
1Hz
143
Backlash decel-
eration stopping
time
0 to 360s
0.5s
144
Speed setting switch-
over
0, 2, 4, 6, 8, 10,
102, 104, 106,
108, 110
4
145
PU
PU display
language
selection
0 to 7
1
Parameter
Name
Setting Range
Initial Value
148
Current detection
Stall prevention
level at 0V input
0 to 220%
150%
149
Stall prevention
level at 10V input
0 to 220%
200%
150
Output current
detection level
0 to 220%
150%
151
Output current
detection signal
delay time
0 to 10s
0s
152
Zero current
detection level
0 to 220%
5%
153
Zero current
detection time
0 to 1s
0.5s
154
Voltage reduction
selection during stall
prevention operation
0, 1
1
155
RT signal function
validity condition
selection
0, 10
0
156
Stall prevention
operation selection
0 to 31, 100, 101
0
157
OL signal output timer
0 to 25s, 9999
0s
158
AM terminal function
selection
1 to 3, 5 to 8, 10
to 14, 17, 18, 21,
24, 32 to 34, 50,
52, 53
1
159
Automatic switchover
frequency range from
bypass to inverter
operation
0 to 10Hz, 9999
9999
160
User group read
selection
0, 1, 9999
0
161
Frequency setting/key
lock operation
selection
0, 1, 10, 11
0
162
Automatic rest
art functions
Automatic restart
after
instantaneous
power failure
selection
0, 1, 2, 10, 11,
12
0
163
First cushion
time for restart
0 to 20s
0s
164
First cushion
voltage for
restart
0 to 100%
0%
165
Stall prevention
operation level
for restart
0 to 220%
150%
166
Output current
detection signal
retention time
0 to 10s, 9999
0.1s
167
Output current detec-
tion operation selec-
tion
0, 1
0
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0, 10, 9999
9999
171
Operation hour meter
clear
0, 9999
9999
172
User group registered
display/batch clear
9999, (0 to 16)
0
173
User group
registration
0 to 999, 9999
9999
Parameter
Name
Setting Range
Initial Value