- 1 -
DIAGNOSIS INFORMATION
LED error indication
LED indication and failures are described in the following table. LED can be reset “automatically”, “by resetting the power” or “by
turning on/off of the main power” after the failure is corrected.
LED Error Indication List
1. POWER, STASUS and FILTER error indications.
Preferen-
tial order
LED Indication
Symptom
Failure
Check Point
Reset
POWER STATUS FILTER
PCB
Reference
1
---
---
---
STBY5 is not
supplied.
Primary power source
failure
POWER,
PFC
F9G0
F9F0
Turning off/on of
the main power
Secondary power source
failure
POWER
LSTBY5
(RH-2)
Turning off/on of
the main power
STBY5 is supplied
LED failure
KEY
D7J5
Turning off/on of
the main power
2
Red / green
---
Green
flash
No power-on
E2P access failure (SCU)
MAIN
IC740
Turning off/on of
the main power
3
Red / green
---
Green
flash 2
No power-on
C/W memory access failure
(SCU)
MAIN
IC740
Turning off/on of
the main power
4
Red / green
---
Green
flash 3
No power-on
E2P access failure (FCU)
MAIN
IC7A0
Turning off/on of
the main power
5
Red / green
---
Green
flash 4
No power-on
E2P access failure (MCU)
MAIN
IC440
Turning off/on of
the main power
6
Red / green
---
Green
flash 5
No power-on
C/W memory access failure
(MCU)
MAIN
IC440
Turning off/on of
the main power
7
Red / green
---
Red
flash
Return to STBY after
the indication of LED
Communication failure
between microcomputers
(FCU/SCU)
MAIN
IC7A0/IC740
Auto
8
Red / green
---
Red
flash 2
Return to STBY after
the indication of LED
Communication failure
between microcomputers
(MCU/SCU)
MAIN
IC440/IC740
Auto
9
Red / green
---
---
No power-on
LBOX/CWBOX/FBOX/
CBOX opened
MAIN
SN, SG, SU
connector
Auto
10 Red / green
---
Orange
flash
Return to STBY after
the indication of LED
Position detection failure of
the mechanical shutter
MAIN
SW
connector
Power-on
again
11 Red / green
Red
flash
Red
flash
Return to STBY after
the indication of LED
Cooling fan (for power)
stopped
MAIN
SFA
connector
Power-on
again
12 Red / green
Red
flash
Red
flash 3
Return to STBY after
the indication of LED
DMD fan stopped
MAIN
MFC connector
SV connector
Power-on
again
13 Red / green
Red
flash
Red
flash 4
Return to STBY after
the indication of LED
CW fan stopped
MAIN
SFD
connector
Power-on
again
14 Red / green
Red
flash
Red
flash 5
Return to STBY after
the indication of LED
Cooling fan (exhaust 1)
stopped
MAIN
DFE connector
SE connector
Power-on
again
15 Red / green
Red
flash 2
Red
flash
Return to STBY after
the indication of LED
Cooling fan (exhaust 2)
stopped
MAIN
DFF connector
SE connector
Power-on
again
16 Red / green
Red
flash 2
Red
flash 2
Return to STBY after
the indication of LED
Upper cooling fan (lamp 1)
stopped
MAIN
SFG
connector
Power-on
again
17 Red / green
Red
flash 2
Red
flash 3
Return to STBY after
the indication of LED
Lower cooling fan (lamp 1)
stopped
MAIN
SFH
connector
Power-on
again
18 Red / green
Red
flash 2
Red
flash 4
Return to STBY after
the indication of LED
Upper cooling fan (lamp 2)
stopped
MAIN
SF1
connector
Power-on
again
19 Red / green
Red
flash 2
Red
flash 5
Return to STBY after
the indication of LED
Lower cooling fan (lamp 2)
stopped
MAIN
SFJ
connector
Power-on
again
20 Red / green
Red flash /
Green flash
---
Return to STBY after
the indication of LED
No LAMP-ON signal
returned
FORMATTER
FW
connector
Power-on
again
21 Red / green
---
Orange
flash 3
Return to STBY after
the indication of LED
C/W stopped
(C/W failure during power-on) FORMATTER
FW
connector
Power-on
again
Summary of Contents for DLP XD8100U
Page 9: ... 4 PCB LOCATION Fig 1 1 2 7 5 8 3 4 6 9 10 11 12 13 14 ...
Page 11: ... 6 EXPOSED VIEW Fig 2 1 5 3 Fx1 Hx2 7 2 Dx2 Cx3 8 Ex1 Gx1 1 Ax1 4 6 Kx2 Jx1 Bx1 9 DLP ASSY ...
Page 13: ... 8 Chassis ASSY 1 Fig 2 2 1 Ax10 Bx2 Cx2 4 5 Fx5 Gx2 Hx2 6 8 9 2 Kx5 Lx3 3 Dx2 7 Jx1 Ex2 ...
Page 15: ... 10 1 Ax5 4 5 6 8 7 Bx2 Cx4 Dx2 Ex4 Hx2 11 2 3 10 9 Hx2 Fx1 Gx2 Chassis ASSY 2 Fig 2 3 ...
Page 22: ... 17 1 2 3 4 5 6 7 8 9 10 E x 2 C x 2 D x 2 B x 2 A x 2 Filter ASSY Fig 2 7 ...
Page 146: ... MEMO ...