- 30 -
17.Removal of the FORMATTER
PCB ASSY
1. Remove the top cover ASSY according to “1. Removal of
the lens ASSY, zoom, focus motor ASSY”.
2. Remove the CW cover unit according to “2. Removal of
the color wheel ASSY”.
3. Remove the
fi
lter cover unit according to “3. Removal of
the ACF SENSOR PCB ASSY”.
4. Remove the top case ASSY according to “4. Removal of
the exhaust fan (front)”.
5. Remove the main top shield according to “5. Removal of
the lamp fan 1”.
6. Remove the terminal ASSY according to “12. Removal of
the KEY PCB ASSY”.
7. Remove the main terminal ASSY according to “13. Re-
moval of the main terminal ASSY”.
8. Remove the two screws (a) and CW plate 2 as shown in
Fig. 3-13.
9. Remove the two screws (b) and CW plate 1 as shown in
Fig. 3-13.
10. Remove the two screws (c) ,two screws (d) and radiator
plate as shown in Fig. 3-13.
11. Disconnect all connectors on the FORMATTER PCB
ASSY.
12. Remove the five screws (e) and FORMATTER PCB
ASSY as shown in Fig. 3-13.
Note: On the back of the FORMATTER PCB ASSY,it is
connected with the DMD PCB ASSY by the board-to-
board connector.When assembling the FORMATTER
PCB ASSY, be sure to attach the board-to-board con-
nector securely.
Fig. 3-13
a
x2
b
x2
c
x2
e
x5
d
x2
CW plate 1
CW plate 2
Radiator plate
FORMATTER PCB ASSY
Summary of Contents for DLP XD8100U
Page 9: ... 4 PCB LOCATION Fig 1 1 2 7 5 8 3 4 6 9 10 11 12 13 14 ...
Page 11: ... 6 EXPOSED VIEW Fig 2 1 5 3 Fx1 Hx2 7 2 Dx2 Cx3 8 Ex1 Gx1 1 Ax1 4 6 Kx2 Jx1 Bx1 9 DLP ASSY ...
Page 13: ... 8 Chassis ASSY 1 Fig 2 2 1 Ax10 Bx2 Cx2 4 5 Fx5 Gx2 Hx2 6 8 9 2 Kx5 Lx3 3 Dx2 7 Jx1 Ex2 ...
Page 15: ... 10 1 Ax5 4 5 6 8 7 Bx2 Cx4 Dx2 Ex4 Hx2 11 2 3 10 9 Hx2 Fx1 Gx2 Chassis ASSY 2 Fig 2 3 ...
Page 22: ... 17 1 2 3 4 5 6 7 8 9 10 E x 2 C x 2 D x 2 B x 2 A x 2 Filter ASSY Fig 2 7 ...
Page 146: ... MEMO ...