4
2.2 Applicable system
This section describes usable modules and cables.
(1) Modules connectable on the branch line side
The types of the modules connectable on the branch line side of the
AJ65BTS-RPH are shown below.
Table 2.1 Modules connectable on the branch line side
(2) Applicable communication cables
The communication cables connectable to the AJ65BTS-RPH are
shown below.
Table 2.2 Applicable communication cables
Category
Module types
Slave station
Remote I/O station
Remote device station
Intelligent device station
Local station
Repeater
AJ65BTS-RPH
AJ65FBTA-RPH
AJ65SBT-RPT
AJ65SBT-RPS/RPG
AJ65BT-RPI-10A/10B
Bridge
AJ65SBT-CLB
Connector
name
Applicable cable
Terminal
resistance
CC-Link version
Name
Trunk line side
Ver.1.00
CC-Link dedicated
high-performance cable
130
Ω
CC-Link dedicated cable
110
Ω
Ver.1.10
CC-Link dedicated cable
Branch line side
Ver.1.00
CC-Link dedicated cable
Ver.1.10
CC-Link dedicated cable
POINT
The master station and stand by master station can not be connected
to the branch line side.