7.1.17 Uploading program, parameter, comment, and device buffer memories
(UploadSegument: Server)
The UpSegument is transmitted from the client after the InitiateUploadSequence terminates normally.
[Parameters required by the client]
•
Access Specification
Specify the Index or Name of the domain specified by InitiateUploadSequence.
Access Specification
Setting value
Index Domain
Index
Variable Name
Domain Name
[Server (AJ71PB96F/A1SJ71PB96F) answer parameters]
•
Load Data
The read data is set.
Note
The AJ71PB96F/A1SJ71PB96F transmits the data in 128 byte units. For this reason, make the
CRL Max send PDU (low) value 200 or more.
•
More Follows
This notifies whether or not data remains to be uploaded.
More Follows value
Meaning
False = 0
No more data remains to be uploaded.
True = FF (hex)
More data remains to be uploaded.