20
21
LINEUP
S F - P R F O B - S C 7K 4P H A
None
F
Symbol Installation method
Foot mounting type
Flange type
None
B
Symbol Classification
Without brake
With brake
None
H
Symbol Classification
200 V class
400 V class
1K
2K
3K
5K
7K
11K
15K
Symbol Output
1.5 kW
2.2 kW
3.7 kW
5.5 kW
7.5 kW
11 kW
15 kW
18K
22K
30K
37K
45K
55K
Symbol Output
18.5 kW
22 kW
30 kW
37 kW
45 kW
55 kW
None
O
P
Symbol
Classification
Indoor type (IP44)
Outdoor type (IP44)
Dustproof/waterproof
type (IP55)
None
T
A
Symbol Protective equipment
Without
Thermostat
Thermistor
Fast-response and high-accuracy vector
control can be performed by the use in
combination with the general-purpose
FR-A800-R2R inverter, plug-in option
(FR-A8AP/A8AL), and control terminal
option (FR-A8TP).
Speed fluctuation ratio:
±0.01% (for power driving)
Fast-response / high-accuracy
vector control
By selecting vector control, constant-
torque continuous operation can be
performed in the range from 0 Hz to 60
Hz (zero speed control and servo lock
are available).
Wide range of constant-
torque characteristics
The premium efficiency motor with
encoder (compatible with IE3) meets
the Top Runner Standard in Japan and
the Energy Independence and Secu-
rity Act (EISA) in the United States.
Energy saving /
CO
2
emission reduction
The motor is used in combination with
an inverter of the same capacity.
Compatibility with the inverter
• Environmental resistance was improved
due to the change from the fan cooled
type to the blower cooled type. The
IP55 compatible motor with an encoder
is now also available.
• With the wire-saving design, improved
reliability can be obtained.
• Anti-corrosive coating (type 3) is also
available.
Improved environmental
resistance
Enables a constant-torque operation in a low-speed range
* The reference torque differs from that of the SF-V5RU series motor.
SF-PR-SC
Continuous
operation torque
100%
(60 Hz reference)
57%
(60 Hz reference)
0
3
60
100
Frequency [Hz]
Torque characteristic diagram
1
1
Standard model
Separated converter type
Features
Features
Features
Features
Mitsubishi high-performance energy-saving motor with encoder
Excellent speed accuracy
Speed control range:
1:1800 (for power driving)
Wide range of speed control
F R - A 8 2 0 - 0.4K - 1 - R2R
00046
0.4K
00023
0.4K
03250
110K
00077
0.75K
00038
0.75K
03610
132K
00105
1.5K
00052
1.5K
04320
160K
00167
2.2K
00083
2.2K
04810
185K
00250
3.7K
00126
3.7K
05470
220K
00340
5.5K
00170
5.5K
06100
250K
00490
7.5K
00250
7.5K
06830
280K
00630
11K
00310
11K
00770
15K
00380
15K
00930
18.5K
00470
18.5K
01250
22K
00620
22K
01540
30K
00770
30K
01870
37K
00930
37K
02330
45K
01160
45K
03160
55K
01800
55K
03800
75K
02160
75K
04750
90K
02600
90K
2
4
Symbol
Voltage class
200 V class
400 V class
0
Symbol Structure/function
Standard model
1
2
Symbol
FM
CA
R2R
Symbol
Dedicated function
Roll to roll
dedicated model
R2R
Roll to roll
dedicated model
None
60
06
*
3
Symbol Circuit board coating
(IEC60721-3-3 3C2/3S2 compatible)
Without
With
With
Plated
conductor
Without
Without
With
- R2R
None
60
06
Symbol Circuit board coating
(IEC60721-3-3 3C2/3S2 compatible)
Without
With
With
Plated
conductor
Without
Without
With
0.4K to 280K
Capacity
*
1
Inverter ND rated
capacity (kW)
00023 to 06830
Inverter SLD
rated current (A)
Description
4
Symbol
Voltage class
400 V class
2
Symbol Structure/function
Separated converter type
1
2
Symbol Type
*
2
FM
CA
315K to 500K
Capacity
*
1
Inverter ND rated
capacity (kW)
Description
Three-phase
400 V class
FR-A840-[]
*
4
Three-phase
200 V class
FR-A820-[]
*
4
07700
315K
08660
355K
09620
400K
10940
450K
12120
500K
Three-phase
400 V class
FR-A842-[]
F R - A 8 4 2 - 315K - 1
*1 Models can be alternatively indicated with the inverter rated current (SLD rating).
*2 Specification differs by the type as follows.
*3 Available for the 5.5K or higher.
*4 For the 75K or higher inverter, or whenever a 75 kW or higher motor is used, always connect a DC reactor (FR-HEL), which is available as an option.
Symbol
Dedicated function
Type
*
2
Terminal FM: pulse train output
Terminal AM: analog voltage output (0 to ±10VDC)
Terminal CA: analog current output (0 to 20mADC)
Terminal AM: analog voltage output (0 to ±10VDC)
FM
(terminal FM equipped model)
CA
(terminal CA equipped model)
Sink logic
Source logic
60 Hz
50 Hz
OFF
ON
9999
(same as the power supply voltage)
8888
(95% of the power supply voltage)
Type
Monitor output
Built-in EMC filter
Initial setting
Control logic Rated frequency
Pr.19 Base frequency voltage
07700 to 12120
Inverter SLD
rated current (A)