When to contact your distributor without delay
Turn off the power switch immediately and inform your dealer in any of the following situations:
The fuse or switch blows continuously.
The cable becomes extremely hot.
The covering of the cable is cracked.
The TV, radio or other equipment
starts to malfunction.
When faulty movement is observed when the ON/OFF button is
pressed, even after pulling out the power plug and restarting the
operation after 3 minutes, the faulty movement does not disappear.
A switch does not activate properly.
You hear a strange noise during operation.
Self diagnosis function
■
We are constantly trying to improve our customer service by installing checking devices that show the type of irregularity of each function
as follows:
RUN light
Blinking (once/8 secs.)
Blinking (twice/8 secs.)
Nature of defect
Irregularity of room temperature sensor
•
Heat exchange sensor short-circuited
•
Faulty connection in the connector
•
Room temperature sensor short-circuited
•
Faulty connection in the connector
Place of defect
TIMER light comes on
Blinking (5 times/8 secs.)
TIMER light
Irregularity of outdoor unit
➩
➩
Irregularity of heat exchange sensor
•
Defective fan motor
•
Defective printed circuit board
Indoor fan motor error
Blinking (6 times/8 secs.)
3 m i n u t e s g o
by, but, why ...
The RUN and TIMER lights on the unit indication section blink
quickly (0.5 secs. ON; 0.5 secs. OFF) and don't work.
Characteristics of HEAT mode operation
Mechanism and capacity of HEAT mode operation
■
Mechanism
•
The unit draws in heat from the cold outside air, transfers it indoors and heats the room. The heating capacity of the heat pump mechanism decreases
when the outside air temperature gets colder.
•
The hot air circulation system takes a while before warming up the room temperature.
•
If the outside temperature becomes extremely low, it would be better to use an additional source of heating.
Defrosting
If the outside temperature becomes low and humidity is high, the heat exchanger in the outdoor unit may frost over, which prevents efficient heating.
If
this happens, the automatic defroster is activated and during defrosting the heating operation stops for 5 to 10 minutes.
•
Both indoor and outdoor fans stop and the RUN light (green) blinks slowly (1.5 secs. ON, 0.5 secs OFF) during defrosting.
•
The outdoor unit may give off some steam during defrosting. This is to help the defrosting process and is not a defect.
•
The HEAT operation resumes as soon as defrosting has been completed.
•
Compressor is defective
•
Lack of oil
•
Capacitor is defective
Fuse often blows
RUN light comes on
P.1-18/E
04.10.19, 10:27 AM
17