The air conditioner does not work at all.

Room temperature cannot

be controlled (too cold)

Has the room temperature
been set to “CONT”?

In the “CONT” mode, the
unit operates continuously,

irrespective of the room

temperature.

If the air conditioner does not

operate properly after you have

checked the above points, or if any
doubt still exists after you have

consulted page 16, or if things

happen as shown on page 17, switch

off the power and contact your
dealer.

Has the timer been set in the

"ON" position?

Has the power switch been
turned off?

Is there a power failure or a
blown fuse?

Has the unit been installed correctly?

Suitable installation position

Is there any obstruction in front of the indoor unit, preventing proper ventilation and functioning?

Don’t install the unit in any of the following places:

Where there is a danger of leaking inflammable gases.

Where there is substantial splashing of oil.

Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulfide gases are generated, or in a seaside resort exposed to

sea breezes. Contact your dealer.

The air conditioner and remote control must be at least 1 metre away from a TV set or radio.

Drain the dehumidified liquid from the indoor unit into a spot that drains well.

Pay attention to operating noises!

When you install the unit, take care to choose a place that can comfortably stand the weight of the unit and does not increase the operating noise or vibration.

If there is any likelihood that vibration may be transmitted through the house, fix the unit with the aid of vibration-proof pads between the unit and the
fittings.

Select a place where cold or hot air and operation noises from the indoor and outdoor units do not cause any inconvenience to your neighbours.

Do not leave any obstacles near the outlet and inlet of the outdoor unit. This may cause malfunctioning and increased operating noise.

If you hear an irregular noise during operation, contact your dealer.

Inspection and maintenance

Dependent upon service conditions and operating environment, the inside of the air conditioner may become dirty after a number of seasons'

service (3 to 5 years). This will reduce performance. In addition to normal cleaning, we would recommend inspection and maintenance. (The air

conditioner has a longer life without any trouble.)

Contact your dealer, or any distributor, for inspection and maintenance. (There will be a charge for this service).

We would recommend inspection and maintenance to be carried out during the off-season.

If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because special
purpose tools are required.

Troubleshooting

Please carry out the following checks before making a service call.

Poor cooling

Poor cooling or heating

Did you leave any doors or

windows open?

Have you set the thermostat at

a suitable temperature?

Is there a heat source in the

room?

Are there too many people in

the room?

Is the air filter clean? (Not

clogged?)

suitable

temperature

Is there any direct sunlight

entering the room?

CONT

ON OFF TIMER

FAN SPEED

ON/OFF

MODE

AUTO

HI

MED

LO

P.1-18/E

04.10.19, 10:27 AM

15

Summary of Contents for SRK20HB

Page 1: ...M KILAVUZU SPL T KL MA This air conditioner complies with EMC Directive 89 336 EEC LV Directive 73 23 EEC Ce climatiseur est conforme la Directive EMC 89 336 EEC LV Directive 73 23 EEC Dieses Kimager...

Page 2: ...Contents Safety Precautions 2 Choice of operation and features 4 Name of each part and its function 5 Operation and indication section for remote control 7 AUTO mode operation procedure 8 Temperature...

Page 3: ...se fire Make sure that you drain the hose properly so that all the water has dripped out Negligence may cause flooding in the room resulting in wet furniture Observe instructions with great care LPG S...

Page 4: ...m it directly at the system This may result in a fire Consult your dealer for repairs to the system Wrong repairs could cause an electric shock fire etc If you notice anything abnormal smell of burnin...

Page 5: ...room temperatures It dehumidifies while keeping room temperature almost constant Page 9 Fanning by circulating room air When stove or other heating equipment is in use switch on fan for efficiency Ch...

Page 6: ...eceiver Air filter Removes dust or dirt from the inlet air Page 14 Air outlet Air blows out of here Left right air flow adjustment fin Page 10 Drain hose Drains water from the dehumidified air Wireles...

Page 7: ...tion Blinks at air flow stop due to the HOT KEEP Page 16 TIMER light yellow Illuminates during TIMER operation ON OFF Unit ON OFF button In emergencies this button can be used for turning on off the u...

Page 8: ...ly model CONT ONOFF TIMER AUTO HI MED LO OPERATION MODE Indicator Indicates selected operation with lamp Auto Cool Fan Dry AIR FLOW Indicator Shows selected flap mode TIMER Indicator TEMPERATURE Indic...

Page 9: ...de HEAT DRY COOL depending on the room temperature when switched on 2 CONT ONOFF TIMER FAN SPEED ON OFF MODE TEMP AIR FLOW SET TIMER TIMER ACL AUTO HI MED LO Air flow direction adjustment procedure Pa...

Page 10: ...button 4 3 AUTO The flap operation as shown above will be repeated Sway operation Flap moves up and down continuously SWING FLAP In COOL DRY and FAN operation In HEAT operation Sway operation The flap...

Page 11: ...hen the next operation is started Recommended angle of the flap when stopping DANGER Avoid constant airflow to the body for hours on end CAUTION Avoid downward blowing operation for hours on end Do no...

Page 12: ...h time the button is pressed the indicator is switched in the order of 1 2 3 11 12 Set at 8 The timer light yellow is on Operation starts 5 to 60 minutes before the set time The TIMER light goes out a...

Page 13: ...g period The life of a battery conforming to JIS or IEC is 6 to 12 months with normal use If used longer or when an unspecified battery is used liquid may leak from the battery causing the remote cont...

Page 14: ...erate the unit only when needed Use the timer properly to operate the unit only when needed Don t drop the remote control Handle with care suitable temperature Clean the filters frequently Clogged fil...

Page 15: ...son At the end of the season 1 Set the temperature switch to continuous and operate FAN mode for half a day 2 The unit uses appr 5W even when the power switch has been turned off during the off season...

Page 16: ...any likelihood that vibration may be transmitted through the house fix the unit with the aid of vibration proof pads between the unit and the fittings Select a place where cold or hot air and operatio...

Page 17: ...onnection of the power plug you cannot re start even if power has been restored The memory circuit of the microcomputer has been wiped out Use the remote control to start the operation again Air is no...

Page 18: ...efective printed circuit board Indoor fan motor error Blinking 6 times 8 secs 3 minutes go by but why The RUN and TIMER lights on the unit indication section blink quickly 0 5 secs ON 0 5 secs OFF and...