24
SRK-GZ
OFF
ON
OFF
0
34
36
25 : 48
35 : 50
Operating pattern
D
range
C
range
B
range
A
range
Inverter frequency
Indoor fan
Outdoor fan
Determination of cooling
oriented dehumidifying
operation range
4th speed
2nd speed
1st speed
Temperature check
3 min.
3 min.
3 min.
3 min.
20 sec.
(b)
Outline of control
(i)
Cooling oriented dehumidifying
Room temperature is checked at 3-minute intervals after selecting the cooling or heating oriented dehumidifying in
order to determine the operation range.
Operation range
D
C
B
A
Low
–1
0
+2
Hight
Room temperature – Setting temperature (deg)
S
SRK25, 35GZ-L1
-1
0
Room temperature - Setting temperature (deg.)
+2
High
Low
55
70
100
Operation range
Relative humidity (%)
I
C
B
A
F
E
D
55
70
Relative humidity (%)
Humidity sensor setting range
High-humidity range (A, B, C, I)
Low-humidity range (D, E, F, I)
Operating pattern
Inverter frequency
(rps)
Indoor fan
7 speed
6 speed
5 speed
4 speed
3 speed
2 speed
1 speed
OFF
2 speed
OFF
Outdoor fan
Determination of cooling
oriented dehumidifying
operation range
60
3 min.
3 min.
3 min.
3 min.
3 min.
3 min.
3 min.
20 sec.
40
14
60
40
14
0
Temperature and humidity check
Temperature and humidity are checked at 3-minute intervals after selecting the cooling or heating oriented dehumidify-
ing in order to determine the operation range.
S
SRK502Z-L
A
range
B
range
C
range
D
range
E
range
F
range
I
range
Summary of Contents for SRC25GZ-L1