23
SRK-GZ
Model
SRK25GZ-L1
SRK35GZ-L1
SRK502Z-L
1 cycle
1 cycle
1 cycle
Item
2 min.
3 min.
2 min.
3 min.
2 min.
3 min.
Inverter frequency
92Hz
102Hz
108rps
Indoor fan
5th speed
6th speed
6th speed
7th speed
6th speed
7th speed
Outdoor fan
ON
ON
Me
(b)
Detail of control in each mode (Pattern)
(i)
Fuzzy operation
During the fuzzy operation, the air flow and the inverter frequency are controlled by calculating the difference between
the room temperature setting correction temperature and the suction air temperature.
(ii)
Cooling thermostat operation
1)
Operating conditions
During the cooling fuzzy operation or when the frequency obtained by the fuzzy calculation is less than -24 Hz.
2)
Detail of operation
(iv) Cooling “HI POWER” operation
(HI POWER button on remote controller: ON)
The unit is operated continuously for 15 minutes regardless of the setting temperature.
1) Detail of operation: Following cycle is repeated 3 times.
(iii) Continuous mode operation
(Temperature setting button on remote controller: Continuous)
(6)
Outline of cooling operation
(a)
Air capacity selection
(i)
Frequency of inverter changes within the range of selected air flow.
Model
Air flow selection
SRK25GZ-L1
SRK35GZ-L1
SRK502Z-L
AUTO
Frequency
34~92Hz
34~102Hz
18~118rps
Air flow
Depends on frequency.
HI
Frequency
34~92Hz
34~102Hz
18~118rps
Air flow
5/6th speed
5/6th speed
5~7th speed
MED
Frequency
34~68Hz
34~86Hz
18~92rps
Air flow
4th speed fixed
4/5th speed
4/5th speed
LO
Frequency
34~44Hz
34~44Hz
18~44rps
Air flow
3/4th speed
3rd speed
3/4th speed
(ii)
When any protective function actuates, the operation is performed in the mode corresponding to the function.
(iii)
Outdoor blower is operated in accordance with the frequency.
Inverter frequency
0Hz [Comp. stopped]
Indoor fan
Corresponds to fan speed switch.
Outdoor fan
Stop
Model
SRK25GZ-L1
SRK35GZ-L1
SRK502Z-L
Item
AUTO
HI
MED
LO
AUTO
HI
MED
LO
AUTO
HI
MED
LO
Inverter frequency
82Hz
68Hz
44Hz
86Hz
52Hz
140rps
90rps
46rps
Indoor fan
5th speed
4th speed
5th speed
3rd speed
8th speed
6th speed 4th speed
Outdoor fan
ON
ON
5th speed
3rd speed 2nd speed
Notes (1) In the continuous mode, the unit is operated with the continuous cooling operation without adjustment of room temperature.
(2) Protective functions will actuate with priority even during the continuous mode operation.
Notes (1) Protective functions will actuate with priority even during the “HI POWER” operation.
(2) Room temperature is not adjusted during the “HI POWER” operation
(3) “HI POWER” operation is prohibited during the operation controlled with the pleasant reservation timer.
Heating oriented dehumidifying
Cooling oriented dehumidifying
Low
–3
High
Room temperature - Setting temperature (deg)
Cooling or heating oriented dehumidifying is selected again one hour after the first selection of the cooling or heating oriented dehumidifying.
(7)
Outline of dehumidifying operation
(a)
After operating the indoor blower for 20 seconds from immediately after the start of operation, the indoor temperature is
checked and, based on the result of check, the cooling oriented dehumidifying or heating oriented dehumidifying is selected.