MICRO 8
Installation and user manual
Page 17 of 24
TX AND RX COLUMN LEDS ENABLED
They show the status of the green and red led on the TX and RX antennas.
To change the on / off condition, place the mouse on the led box whose status you want to change
(figure 1) and click once (figure 2).
The flag in the box indicates the led are lit.
To save the modification, click with the mouse on the red cell of the address you are configuring
(figure 4).
RX LEVEL COLUMN
Displays the level of the RX signal.
The values entered in this column cannot be changed.
INTRUDER SPEED COLUMN
Displays the time (in mS) of the duration of the attenuation of the alarm signal.
To change this parameter, place the mouse on the cell of the address you want to modify and click once
(figure 1).
Wait for the control window to open (figure 2) and enter a value between 20 and 350, then click OK
(figure 3).
To save the modification, click with the mouse on the red cell of the address you are configuring
(figure 4).
COLUMN ALARM OFFSET
Displays the level (in dB) of attenuation of the alarm signal.
To change this parameter, place the mouse on the cell of the address you wish to modify and click once
(figure 1). Wait for the control window to open (figure 2) and enter a value between -20 and -1, then
click OK (figure 3).
To save the modification, click with the mouse on the red cell of the address you are configuring
(figure 4).
Figure 1
Figure 2
Figure 3
Figure 1
Figure 2
Figure 3
Figure 4
Figure 1
Figure 2
Figure 4
Figure 3