MICRO 8
Installation and user manual
Page 14 of 24
By using the SENS LEVEL dip-switches on the RX board , you can set the signal attenuation level.
Procedure:
1. Enter the configuration mode (CNF in ON) and wait for the led to stop flashing.
2. Program the two dip-switches following the combinations indicated in the following table:
3. Exit the configuration mode by programming the CNF dip-switch in OFF mode, avoiding
interrupting the signal and moving the antenna.
RX board - signal attenuation level setting
DIP 1
DIP 2
OFF
OFF
Minimal Sensitivity (-5db)
ON
OFF
(-3,8 db)
OFF
ON
(-2,5 db)
ON
ON
Maximum Sensitivity (-1,5db)
By using the SENS TIME dip-switches on the RX board , it is possible to set the duration of the signal
attenuation.
Procedure:
1. Enter the configuration mode (CNF in ON) and wait for the led to stop flashing.
2. Program the two dip-switches following the combinations indicated in the following table:
3. Exit the configuration mode by programming the CNF dip-switch in OFF mode, avoiding
interrupting the signal and moving the antenna.
RX board - duration setting of signal attenuation
DIP 1
DIP 2
OFF
OFF
50 mS
ON
OFF
150 mS
OFF
ON
250 mS
ON
ON
350 mS
TX board - 4dB transmission level attenuation setting
By using the SENS LEVEL dip-switches on the TX board , the signal transmission level can be
attenuated by 4 dB.
Procedure:
1. Enter the configuration mode (CNF in ON) and wait for the led to stop flashing.
2. Program the two dip-switches in ON mode (the red led will switch off).
3. Exit the configuration mode by programming the CNF dip-switch in OFF mode, avoiding
interrupting the signal and moving the antenna.
IMPORTANT
It is only possible to enter the configuration mode once to program the dip-switches.
In manual control mode it is not possible to make changes using the software.