FA-106 Installation and Operation Manual

19

13.

Wireless Devices Placement Proximity.  

Moreover all wireless devices must be a minimum and 

maximum distance away from large metal objects, such as refrigerators.  You are required to 
consult the specific Mircom System manual and application guide for any maximum distances 
required between devices and suggested placement of wireless devices for optimal functioning.  

14.

Failure to Trigger Sensors.  

Moreover, Mircom Systems may fail to operate as intended if 

motion, heat, or smoke sensors are not triggered.  

a. Sensors in a fire system may fail to be triggered when the fire is in a chimney, walls, roof, or 

on the other side of closed doors.  Smoke and heat detectors may not detect smoke or heat 
from fires on another level of the residence or building.  In this situation the control panel 
may not alert occupants of a fire.  

b. Sensors in a nurse call system may fail to be triggered when movement is occurring outside 

of the motion sensors’ range. For example, if movement is occurring on the other side of 
closed doors or on another level of the residence or building the motion detector may not be 
triggered.  In this situation the central controller may not register an alarm signal.

15.

Interference with Audible Notification Appliances.  

Audible notification appliances may be 

interfered with by other noise sources such as stereos, radios, televisions, air conditioners, 
appliances, or passing traffic.  Audible notification appliances, however loud, may not be heard by 
a hearing-impaired person.

16.

Other Impairments.  

Alarm notification appliances such as sirens, bells, horns, or strobes may 

not warn or waken a sleeping occupant if there is an intervening wall or door.  It is less likely that 
the occupants will be alerted or awakened when notification appliances are located on a different 
level of the residence or premise.

17.

Software Malfunction.  

Most Mircom Systems contain software.  No warranties are provided as 

to the software components of any products or stand-alone software products within a Mircom 
System.  For a full statement of the warranties and exclusions and limitations of liability please 
refer to the company’s standard Terms and Conditions and Warranties.  

18.

Telephone Lines Malfunction.  

Telephone service can cause system failure where telephone 

lines are relied upon by a Mircom System. Alarms and information coming from a Mircom System 
may not be transmitted if a phone line is out of service or busy for a certain period of time. Alarms 
and information may not be transmitted where telephone lines have been compromised by 
criminal tampering, local construction, storms or earthquakes.

19.

Component Failure.

  Although every effort has been made to make this Mircom System as 

reliable as possible, the system may fail to function as intended due to the failure of a component.

20.

Integrated Products.  

Mircom System might not function as intended if it is connected to a non-

Mircom product or to a Mircom product that is deemed non-compatible with a particular Mircom 
System.  A list of compatible products can be requested and obtained.

Warranty

Purchase of all Mircom products is governed by:

https://www.mircom.com/product-warranty

https://www.mircom.com/purchase-terms-and-conditions

https://www.mircom.com/software-license-terms-and-conditions

Summary of Contents for FA-103

Page 1: ...FA 103 and FA 106 Fire Alarm Control Panels LT 1200 Rev 2 March 2018 Installation and Operation Manual Advanced Life Safety Solutions...

Page 2: ......

Page 3: ...ation 9 Trouble Indicators and Controls 11 Common Trouble LED 11 Buzzer Buzzer Silence Pushbutton 11 Detection Zone Trouble LED 11 Ground Fault LED 11 Battery Fault LED 11 Detection Zone Disable 11 Se...

Page 4: ...Figure 3 Conduits for Wiring 4 Figure 4 Setting the DIP Switch functions 5 Figure 5 A C Power and Battery Connection 6 Figure 6 Circuit Board Layout 7 Figure 7 Detection and signal wiring 8 Figure 8 A...

Page 5: ...pt the FA 103 is depopulated and has terminal connections for three detection zones only Use of the reference the panel will apply to both models FA 106 and FA 103 Models available are Mechanical Inst...

Page 6: ...2 Figure 1 Backbox and flush trim mounting details 13 3 4 12 3 4 1 11 16 Optional flush mounting trim model FA 102TR Four 7 32 dia mounting holes 2 7 8 7 1 8 1 1 4 10 3 8...

Page 7: ...3 Figure 2 Assembly of FA 106 and FA 103 Fire Alarm Panels Inner Dead Front Outer Front Door...

Page 8: ...dedicated conduit in knockouts A or B shown in Figure 3 All other circuits are current limited and must be run through knockouts C or D Figure 3 Conduits for Wiring Clearances The controls shall be n...

Page 9: ...age which will be connected to the fire alarm panel INPUT VOLTAGE DIP SWITCH SW12 7 DIP SWITCH SW12 8 120V OFF OFF 240V ON OFF 220V OFF ON 1 2 3 4 5 6 7 8 ON Alarm Relay ON Disconnects the Alarm Relay...

Page 10: ...r contact location and designation Remote Annunciation Annunciation outputs are provided for connection to an RTI 1 Remote Trouble indicator Refer to Figure 8 on page 10 for wiring instruction A C Pow...

Page 11: ...ZONES 1 TO 6 DIP SWITCH SW12 ALARM LED per Zone TROUBLE LED per Zone Space for Detection Zone label NAC active red LED and NAC yellow trouble LED per NAC zone The battery fuse protects against batter...

Page 12: ...24VDC Regulated 50mA max alarm 24VDC Regulated 50mA max alarm 24VDC Regulated 50mA max alarm 24VDC Regulated 50mA max alarm 24VDC Regulated 50mA max alarm 24VDC Regulated 50mA max alarm 24V RMS FWR 1...

Page 13: ...Run to Last Device ELR AWG ft m 18 7560 2300 16 12000 3600 14 19000 5800 12 30400 9200 Note Maximum loop resistance should not exceed 100 ohms Total Signal Load Maximum Wiring Run to Last Device ELR...

Page 14: ...zzer 24V 24VDC 250mA max Resettable or Always ON 24V 24VDC 250mA max GND Not used GND ELR 3 9K 1 2 W RTI 1 BLACK BLUE RED WHITE Resettable Aux 24V DC Resettable Aux 24V DC TO DETECTION ZONE POWER LAST...

Page 15: ...across into the front display Ground Fault LED Any ground fault of 1K ohms or less will flash the yellow Ground Fault LED flash the yellow Common Trouble LED and sound the common trouble buzzer inter...

Page 16: ...NOTE The CPU FAIL LED will not illuminate during Lamp Test System Checkout Before turning the power on 1 Check all external wiring for opens shorts or grounds 2 Check that transformer cables are secu...

Page 17: ...rm 1 zone active 95mA 2 zone active 136mA 3 zone active 177mA 4 zone active 218mA Zones 4 to 6 not available on the FA 103 5 zone active 259mA 6 zone active 300mA Maximum current of Aux Power and Dete...

Page 18: ...ircom System Sensor i3 MIR 525 30 C2W BA c w base 30 MIR 525T 30 C2WT BA c w base 30 Apollo System Sensor Series 60A Bases 45681 200 220 232 251 1400A 30 Series 65A Bases 45681 255 256 257 258 2400A 2...

Page 19: ...2451A B401A 25 DS282TH 30 2451THA B401A 25 Siemens 5451A B401BA 25 HI121 DB 11 DB 11C 20 5451A B401A 25 OH121 DB 11 DB 11C 20 5451A B406BA 25 OP121 DB 11 DB 11C 20 Sentrol ESL 429CST 30 429CRT 30 713...

Page 20: ...must provide a dedicated continuous power without provision of any disconnect devices Use 12 AWG wire with 600 volt insulation and proper over current circuit protection that complies with the local...

Page 21: ...fe insurance Nor is the system a substitute for property owners renters or other occupants to act prudently to prevent or minimize the harmful effects of an emergency situation Building automation sys...

Page 22: ...ay not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical cir...

Page 23: ...nts Alarm notification appliances such as sirens bells horns or strobes may not warn or waken a sleeping occupant if there is an intervening wall or door It is less likely that the occupants will be a...

Page 24: ...Tel 888 660 4655 905 660 4655 Fax 905 660 4113 Mircom 2018 Printed in Canada Subject to change without prior notice www mircom com U S A 4575 Witmer Industrial Estates Niagara Falls NY 14305 Tel 888 6...

Reviews: