background image

Hardware Description & Installation Manual

M809-9900-120

27 March 2014

Summary of Contents for Kaleido-X

Page 1: ...Hardware Description Installation Manual M809 9900 120 27 March 2014 ...

Page 2: ...ssion and license to owners of Kaleido X multiviewers to use their product manuals for their own internal business use Manuals for Miranda products may not be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose unless specifically authorized in writing by Miranda A Miranda manual may have been revised to reflect change...

Page 3: ...ng instructions unless you are qualified to do so Refer all servicing to qualified service personnel Disconnect both power supply units before servicing Servicing should be done in a static free environment Battery handling There is a danger of explosion if the battery is replaced incorrectly Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used ...

Page 4: ...cker EN 61000 4 2 Electrostatic discharge immunity EN 61000 4 3 Radiated radio frequency electromagnetic field immunity EN 61000 4 4 Electrical fast transient burst immunity EN 61000 4 5 Surge transient immunity EN 61000 4 6 Conducted disturbances immunity EN 61000 4 11 Voltage dips short interruptions and voltage variations immunity ...

Page 5: ...allation 3 Frame and Electrical Installation 4 Kaleido X Cards 10 Maintenance 24 2 Specifications 27 Kaleido X Inputs 27 Kaleido X Outputs 30 Kaleido X Control 31 Kaleido X 4RU Frame 32 Appendix Disposal and Recycling Information 35 Contact Us 37 Table of Contents ...

Page 6: ......

Page 7: ...nitoring and routing solution As a multi image processor it offers the highest level of signal flexibility Each chassis can display 32 HD SD or Analog inputs any number of times in any size across 4 displays of any resolution and orientation Features Unmatched flexibility Any source can be repeated to any position to any display at any size at any resolution without blocking or grouping restrictio...

Page 8: ...could be anywhere with internet access to the network The diagram below shows the Kaleido X multiviewer system and its inputs and outputs Examples of the various external devices that connect to the multiviewer are also shown Multi room layouts Intuitive layout editor software allows rapid creation of multi room layouts which can be recalled quickly from networked remote control panels Highly robu...

Page 9: ...are the Kaleido X User s Manual database samples Quick Start guides and hardware reference manuals for all multiviewer models Keyboard Mouse Note Inline withour commitment toenvironmental preservation only the Quick Start Guide for your multiviewer model and some ancillary documents e g welcome letters warranty cards are distributed in printed form All manuals and the Release Notes are available o...

Page 10: ...nnectors which are mounted on a connector panel These connector panels are installed from the rear of the frame in the same vertical position as their associated card The redundant power supplies are installed in the lower right hand corner of the frame The hinged front door can be opened to give access to the cards The Kaleido X 4RU frame incorporates the following key elements A rack mountable m...

Page 11: ...mal performance it is strongly recommended that you operate the Kaleido X in an environment with an ambient temperature lower than 20 ºC 68 ºF Slot Function Color code Card type 1 Main Grey KXA GPI GEN 2 Output A Yellow KXO Dual3 KXO Dual 3 Output B 4 Input A Green KXI 16HSV3 KXI 16HSV KXI 16HS3 KXI 16HS KXI 16SV 5 Input B 6 Option A Mauve Future Use 7 Option B IMPORTANT When measuring the ambient...

Page 12: ...re installed and removed from the front of the frame and are hot swappable so that a defective supply may be replaced without removing the Kaleido from service Access the power supplies by opening the front door of the frame PSU A is located on the top and PSU B is located on the bottom Removing a Power Supply To remove a power supply 1 Open the front door of the frame and locate the two power sup...

Page 13: ...connectors have mated with the frame s sockets and the power supply will go in no further 4 Use the captive screw in the rotating handle to secure the power supply in position Operation Separate AC connectors are provided for the two power supplies and are located at the bottom left of the rear of the frame as seen from the rear Connect both power supplies to an appropriate power source using the ...

Page 14: ...rough a grille and filter in the front door and exhaust it through the grate on the side of the frame Power Supply Cooling Fans Each power supply has two fans located on the front of the supply In addition there is a fan located on the rear panel directly behind the power supplies beside the AC connectors IMPORTANT The Kaleido X requires a constant flow of cooling air during operation DO NOT OPERA...

Page 15: ... previously installed card using a screwdriver to loosen the two captive screws 2 Position the new rear panel in the vacant location so its connectors are aligned with the corresponding plugs and push it gently into place so the connectors mate 3 Secure the panel in place using a screwdriver to tighten the two captive screws Removing a Card To remove a card 1 Open the front door of the frame and l...

Page 16: ... provided with a complete set of connectors The KXO Dual and KXO Dual3 are multi function cards that perform a significant portion of the signal processing required to create the monitor wall output They incorporate a mezzanine card mounted on the component side Each output card is complemented by a rear panel KXO Dual R that holds all input and output connectors associated with the card Output ca...

Page 17: ...e Kaleido X User s Manual for details Rear Panel Connections The rear panel layout is divided into three areas Head 1 Head 2 and Control Head 1 The connectors located at the top of the rear panel right hand side when the card is horizontal and you can read the connector labels normally are the Head 1 connectors Notes Be careful to install the rear panel in the matching location at the rear of the ...

Page 18: ...l HD output signal for monitoring purposes DVI IN 1 DVI IN 2 DVI DVI input signal that can be used as a background in the monitor wall display in place of the internally generated background DVI D OUT 1 DVI D OUT 2 DVI DVI digital output no analog signal on this connector RGBHV OUT 1 RGBHV OUT 2 DE 15S High resolution analog component output to feed the monitor wall display ANALOG OUT 1 L ANALOG O...

Page 19: ...use keyboard or USB key for software upgrade or data backup There are three other USB ports accessible on the front of the card that serve the same functions RS 422 RJ 45 see note below Connect to an RS 422 SMPTE ST 207 EBU 3245 or RS 485 device or network Note The Kaleido X s RS 422 ports have an RJ 45 connector in order to preserve space on a busy panel The RS 422 interface specifies a DE 9 conn...

Page 20: ...Routers chapter of the Kaleido X User s Manual Front Card Edge Layout The following diagram shows the various indicators connectors and buttons that appear on the output cards front edge Note The RS 422 port on the multiviewer side has no ground pin Using the appropriate DE 9S to RJ 45 adapter an external device should be able to communicate with the multiviewer despite the lack of a ground Pinout...

Page 21: ...r for special circumstances One exception is the recessed USB connector which can be used to hold a USB key that can be left in place during operation with the door closed Connector label Connector type Function USB 1 USB 2 and USB 4 USB A Connect a mouse keyboard or USB key for software upgrade or data backup unlabeled ICAT for factory use only Status LEDs Card CPU DVI 1 DVI 2 LTC 1 LTC 2 LTC 3 B...

Page 22: ...g up Kaleido X Software is starting Kaleido X Software is up and running Software upgrade in progress DVI 1 Off Green Orange No input DVI input detected on Head 1 Test DVI 2 Off Green Orange No input DVI input detected on Head 2 Test LTC 1 Green Red Valid LTC signal at LTC 1 input No LTC signal or invalid signal at LTC 1 input LTC 2 Green Red Valid LTC signal at LTC 2 input No LTC signal or invali...

Page 23: ...f the frame The GPI Genlock card is connected to the other cards in the Kaleido X frame through the frame s internal midplane See Card Installation and Replacement on page 9 for instructions on installing the card and the rear panel Rear Panel Connections External connections to the GPI Genlock card are made through connectors mounted on the KXA GPI GEN R rear panel These connectors carry both inp...

Page 24: ...directional connections GPI B 1 24 DB 50 female GPI B input output bidirectional connections GPI C 1 24 DB 50 female GPI C input output bidirectional connections REF INPUT BNC Reference signal to genlock the multiviewer to the local plant Supported Reference formats SMPTE ST 170 SMPTE ST 318 ITU 624 4 BUT 470 6 PAL and NTSC composite sync SMPTE ST 274 SMPTE ST 296 SMPTE ST 240 Pinout for GPI A GPI...

Page 25: ...nections are well established In the following example the goal is to trigger a relay and light up a light 12 7P 29 8P 46 9P 13 4N 30 5N 47 6N 14 4P 31 5P 48 6P 15 1N 32 2N 49 3N 16 1P 33 2P 50 3P 17 GND 34 GND CAUTION In the example below make sure your P and N connections are in the proper polarity otherwise your GPI output will always be in the ON state Pinout for GPI A GPI B and GPI C connecto...

Page 26: ...minal connections Each column on the terminal block has 6 positive and 6 negative terminal connections that correspond to each pin position Negative pins labelled with an N on the Terminal Block Adapter are not used as connections Positive pins labelled with a P and Ground pins labelled with a GND correspond to GPI IN connections Front Card Edge Layout The following diagram shows the indicators an...

Page 27: ...tion of this card are accomplished using external controllers e g the XEdit software and are documented in their respective manuals LED label LED color Interpretation Card status Green Red Blinking Red OK Configuration failed System upgrade in progress Reference input status Green Off Red Orange OK No input Signal not recognized Frame rate not supported Button label Function Reset Reset the FPGA a...

Page 28: ...nput cards can be installed in any of the two available Input slots in the front of the Kaleido X frame These slots are color coded GREEN on the front and rear panel of the frame Every input card is connected to the other cards in the Kaleido X frame through the frame s internal midplane External connections to a KXI 16 card are made through connectors mounted on the associated KXI 16 R rear panel...

Page 29: ...the front end of the KXI 16 input cards Connector label Connector type Function IN 1 to IN 16 BNC HD SD SDI or composite video inputs 1 to 16 SDTI IN BNC Multiplexed audio from an external audio box Audio Bridge Terminal Bottom of panel Top of panel Status LEDs Card SDTI Reset Button IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10 IN 11 IN 12 IN 13 IN 14 IN 15 IN 16 ...

Page 30: ... the door To clean the air filter 1 Remove the door from the frame by opening it and lifting it straight up 2 Place the door flat on a work surface with the inside of the door facing up 3 Using a vacuum cleaner with a brush nozzle to prevent scratching vacuum the dust from the inner side of the door 4 Turn the door over and vacuum the outer side of the door 5 Reinstall the door on the frame by pos...

Page 31: ... power supply Replacing a Defective Cooling Fan The primary cooling fans for the Kaleido X frame are located in a module on the left hand side of the frame Eight fans are mounted in a removable assembly To remove the fan assembly 1 Power off the entire frame by unplugging the AC cords 2 Release the two captive mounting screws at the top and bottom of the fan assembly IMPORTANT The Kaleido X requir...

Page 32: ...tive screws 4 Power up the frame by plugging in the AC cords 5 Verify that all eight fans are running properly In some cases there may be incidental contact between the screws holding the fans in place on the fan module and the edge of the card slot assembly Pull firmly to remove the module Note In some cases there may be incidental contact between the screws holding the fans in place on the fan m...

Page 33: ...wo fields if the video inputs are genlocked and two or three fields if the video inputs are not genlocked Signal inputs require BNC connectors Composite Inputs KXI 16HSV3 KXI 16HSV KXI 16SV Signal NTSC SMPTE ST 170 NTSC J PAL BGDHI PAL N PAL M SECAM Return loss 25 dB up to 5 75 MHz Quantization 8 bits Impedance 75 SD SDI Inputs KXI 16HSV3 KXI 16HSV KXI 16HS3 KXI 16HS KXI 16SV Signal 4 2 2 SMPTE ST...

Page 34: ... 94 are reported as 1080i59 94 on the monitor wall and in XAdmin s Status and Options page Audio SMPTE ST 299 Return loss 12 dB up to 1 485 GHz Jitter 0 2 UI Cable length 100 m 328 ft Belden 1694A 3G SDI Inputs KXI 16HSV3 KXI 16HS3 Signal 4 2 2 SMPTE ST 424 2006 2 97 2 97 1 001 Gbps Formats SMPTE ST 425 2008 level A and level B single stream 1080p50 1080p59 94 Audio SMPTE ST 299 Return loss 15 dB ...

Page 35: ...5 2005 up to 128 channels 64 AES Cable length 250 m 820 ft Belden 1694A Connector BNC Reference Inputs Supported formats SMPTE ST 170 SMPTE ST 318 ITU 624 4 BUT 470 6 PAL and NTSC composite sync SMPTE ST 274 SMPTE ST 296 SMPTE ST 240 Connector BNC DVI D Inputs Signal DVI D Resolution From 1024 768 to 1920 1200 NI H frequency 37 kHz to 96 kHz Refresh rate 50 59 94 Hz Cable length 3 6 m 12 ft with A...

Page 36: ... WECO www weco ca Plug in Screw Connector System for Printed Circuit Boards Type 930 HFL DS 930 931 HSL Ω Progressive RGBHV Outputs Signal Analog RGBHV Resolution From 1024 768 to 1920 1200 NI H frequency 31 kHz to 96 kHz Refresh rate 50 59 94 Hz Level 0 7 Vp p Connector DE 15S female DVI Outputs Signal DVI D Resolution From 1024 768 to 1920 1200 NI H frequency 37 kHz to 96 kHz Refresh rate 50 59 ...

Page 37: ...p 1 pair 1 Cable length 100 m 328 ft Belden 1694A Jitter 0 2 UI p p wideband Connectors BNC Analog Audio Outputs Signal Balanced analog stereo Impedance 600 Level 24 dBu maximum Connector WECO AES Outputs Signal AES3 Impedance 110 Connector WECO Option Outputs Future Use Connector RJ 45 HD SDI Outputs continued Ω Ω GPI bidirectional up to 72 Description Contact closure to GND Signal Open collector...

Page 38: ...l RS 422 SMPTE ST 207 EBU 3245 RS 485 Connector RJ 45 USB 4 connectors Signal USB Version 1 0 Connector USB Power supply Hot swappable redundant power supply Input voltage 90 264 V Frequency 47 63 Hz Max current 15A Max Power out 1200 W 230 Vac Dimensions H 175 mm 7 in 4 RU W 448 mm 17 64 in mounting flange for standard 19 in rack D 527 mm 20 75 in Full spec temperature range 0 35 C 32 F 95 F ambi...

Page 39: ...Weight typical configuration 2 power supplies 1 fan 3 cards 19 42 kg 42 8 lbs Component weight 1 fan 0 9 kg 2 lbs 2 power supplies 3 4 kg 7 5 lbs KXO Dual including rear 2 25 kg 5 lbs KXI including rear 2 1 kg 4 6 lbs KXI GPI GEN including rear 0 77 kg 1 7 lbs ...

Page 40: ......

Page 41: ... environmental laws and guidelines WARNING Be careful not to short circuit the batteries by adhering to the appropriate safe handling practices Do not dispose of batteries in a fire as they may explode Batteries may explode if damaged or overheated Do not dispose of batteries as household waste Do not dismantle open or shred batteries Keep batteries out of the reach of children The electrolyte of ...

Page 42: ...ry is mechanically or electrically abused The most likely risk is acute exposure when a cell vents In the event of a battery leak do not allow battery liquid to come in contact with skin or eyes Seek medical help immediately in case of ingestion inhalation skin or eye contact or suspected exposure to the contents of an opened battery WARNING continued ...

Page 43: ...1 514 335 1614 E mail support miranda com Asia Office hours 9 00 a m 5 00 p m GMT 8 Telephone 852 2539 6987 Fax 852 2539 0804 E mail asiatech miranda com Europe Middle East Africa UK Office hours 9 00 a m 6 00 p m GMT Telephone 44 118 952 3444 Fax 44 118 952 3401 E mail eurotech miranda com China Telephone 86 10 5873 1814 E mail asiatech miranda com France Office hours 9 00 a m 5 00 p m GMT 1 Tele...

Reviews: