7
SPECIFICATIONS
1. Plumbing
1.1.
Minimum maintained inlet pressure of 70 kPa (0.7 bar). 100 kPa (1.0 bar)
recommended for satisfactory operation.
1.2.
Maximum static inlet pressure of 1000 kPa (10 bar).
1.3.
Minimum static inlet pressure of 20 kPa (0.2 bar) to keep the inlet valve
closed.
2. Electrical
2.1.
The Mira Sport Thermostatic 9.0 kW @ 240 V AC (8.2 kW @ 230 V AC) requires
a 40 Amp circuit protection device.
The Mira Sport Thermostatic 9.8 kW @ 240 V AC (9.0 kW @ 230 V AC) requires
a 45 Amp circuit protection device.
2.2.
The terminal block will accept cable up to 16 mm
2
(9.0 and 9.8 kW).
2.3.
The Mira Sport Thermostatic is suitable for installation within zone 1 and is
rated IPx4.
3. Standards and Approvals
3.1.
The Mira Sport Thermostatic complies with all relevant directives for CE
marking.