background image

32

1060735-W2-E (1563) (J95E/F)

© Kohler Mira Limited, February 2011

CUSTOMER SERVICE

Guarantee

Your  product  has  the  benefit  of  our  manufacturer’s 

guarantee which starts from the date of purchase.

To activate this guarantee, please return your completed 

registration  card,  visit  our  website  or  free  phone  0800 

0731248 within 30 days of purchase (UK only).

Within  the  guarantee  period  we  will  resolve  defects  in 

materials or workmanship, free of charge, by repairing or 

replacing parts or product as we may choose.

If you have not previously activated the guarantee, you will 

be required to do so prior to the provision of assistance. 

If you do not activate your guarantee our Engineer will be 

entitled  to  charge  full  payment  for  the  visit  (Call  out  fee 

plus parts).

This guarantee is in addition to your statutory rights 

and is subject to the following conditions:

  ●  The  product  must  be  installed  and  maintained  in 

    accordance  with  the  instructions  given  in  this  user   

    guide.

  ●  Servicing  must  only  be  undertaken  by  us  or  our   

    appointed  representative. 

Note!

  if  a  service  visit   

    is  required  the  product  must  be  fully  installed  and   

    connected to services.

  ●  Repair under this guarantee does not extend the original

    expiry date. The guarantee on any replacement parts  

    or product ends at the original expiry date.

  ●  For  shower  fi ttings  or  consumable  items  we  reserve  

    the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such  as 

damage or performance issues arising from incorrect 

installation, improper use, lack of maintenance, build up 

of limescale, frost damage, corrosion, system debris or 

blocked fi lters) or where no fault has been found with 

the product.

  ●  Water or electrical supply, waste and isolation issues.

  ●  Compensation  for  loss  of  use  of  the  product  or 

consequential loss of any kind.

  ●  Damage or defects caused if the product is repaired 

or  modifi ed  by  persons  not  authorised  by  us  or  our 

appointed representative.

  ●  Routine maintenance or replacement parts to comply 

with the requirements of the TMV 2 or TMV 3 healthcare 

schemes. 

What to do if something goes wrong

If your product does not function correctly when you fi rst 

use  it,  contact  your  installer  to  check  that  it  is  installed 

and commissioned in accordance with the instructions in 

this manual. Should this not resolve the issue, contact our 

Customer Services Team who will offer you or your installer 

advice and if applicable arrange for a Service Technician to 

call. If the performance of your product declines, check in 

this manual to see if simple home maintenance is required. 

If you require further assistance call our Customer Services 

Team.

Extended Guarantees

A selection of protection plans are available that 

enable you to cover repair bills for the life of your policy 

(excludes Eire). Ring 01922 471763 for more details.

Helpdesk Service

Our dedicated Customer Services Team is comprehensively 

trained  and  can  offer  help  and  advice,  spare  parts, 

accessories or a service visit. We will need you to have your 

model name or number, power rating (if applicable) and date 

of purchase. As part of our quality and training programme 

calls may be recorded or monitored.

Mira Showers Website 

(www.mirashowers.co.uk)

From  our  website  you  can  register  your  guarantee, 

download additional user guides, diagnose faults, purchase 

our full range of accessories and popular spares, refer to 

our FAQ’s and request a service visit.

Spares and Accessories

We  maintain  extensive  stocks  of  genuine  spares  and 

accessories  and  aim  to  provide  support  throughout  the 

product’s expected life. Payment can be made by phone 

at time of order using most major Credit or Debit cards and 

we aim to despatch orders within two working days. Items 

purchased from us are guaranteed for 12 months from date 

of purchase. For safety reasons spares exposed to mains 

voltages should only be fi tted by competent persons.

Returns

 – items can be returned within one month of date of 

purchase, providing that they are in good condition and the 

packaging is unopened. Please obtain authorisation from 

our Customer Services Team before return. We reserve the 

right to apply a 15% restocking charge.

Service / Repairs

We have a nationwide team of Service Technicians who can 

carry out all service or repair work to your product within the 

guarantee period and beyond. You have the assurance of a 

fully trained Mira Technician, genuine Mira spare parts and 

a 12 month guarantee on any chargeable work done.

Payment should be made directly to the Service Technician 

who will accept most major Credit or Debit cards.

To Contact Us

UK

Telephone: 0844 571 5000

www.mirashowers.co.uk

E-mail: [email protected]

Fax: 01242 282595

By Post: Mira Customer Services Dept, Cromwell Road, 

Cheltenham, Gloucestershire, GL52 5EP

Eire

Telephone: 01 459 1344

E-mail: [email protected]

Fax: Dublin 01 459 2329

By Post: Modern Plant Ltd (Dublin),

Otter House, Naas Road, Clondalkin, Dublin 22

Mira is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

product specifi cations without notice.

FM 14648

Summary of Contents for Sport Thermostatic 9.0

Page 1: ...1 Installation User Guide These instructions are to be left with the user 9 0 9 8 K W MIRA SPORT THERMOSTATIC ELECTRIC SHOWER...

Page 2: ...ation 12 Commissioning 14 User Instructions 16 Thermostatic Control 17 Fault Diagnosis 20 Maintenance 24 Inlet Filter Cleaning Renewing 24 Dimensions 25 Spare Parts 26 Accessories 28 Wiring Diagram 29...

Page 3: ...h Mira Sport Thermostatic 9 8 A 9 8 kW 240 V AC 9 0 kW 230 V AC heater Available in white chrome finish Recommended Usage Domestic Light Commercial Heavy Commercial Healthcare Guarantee For domestic i...

Page 4: ...ust be local to the appliance and may be a ceiling mounted pullcord type or a wall mounted switch fitted in an appropriate zone area 7 In accordance with BS7671 a 30mA Residual Current Device RCD must...

Page 5: ...dren should be supervised to ensure that they do not play with the shower 20 Always switch off the shower at the electrical isolating switch when not in use 21 The showerhead must be de scaled regular...

Page 6: ...rt names and to confirm that the parts are included q 1 x Olive Documentation q 1 x Customer Support Brochure q 1 x Installation Template q 1 x Installer Checklist q 1 x Compression Nut q 3 x Fixing S...

Page 7: ...cal 2 1 The Mira Sport Thermostatic 9 0 kW 240 VAC 8 2 kW 230 VAC requires a 40 Amp circuit protection device The Mira Sport Thermostatic 9 8 kW 240 VAC 9 0 kW 230 VAC requires a 45 Amp circuit protec...

Page 8: ...chment area 5 Fitted to finished wall surface 6 No sharp hose kinks 7 Fittings should be positioned with a greater than 25 mm gap If this is not achievable then a outlet double checkvalve must be fitt...

Page 9: ...an air gap must be left behind the appliance 6 Avoid layouts where the shower hose will be sharply kinked This may reduce the life of the hose 7 A Soap Dish Hose Retaining Ring is supplied to prevent...

Page 10: ...2 Shower unit is earthed 3 The minimum required supply cable size must conform to BS 7671 4 Double pole isolating switch 5 Do not twist live or neutral cable cores 6 Electrical connections are tightl...

Page 11: ...size of 4 0 mm if the cable is not mechanically protected 2 5 mm if mechanically protected 3 Supply cable see opposite 4 As a guide only and in accordance with BS 7671 we recommend close circuit prote...

Page 12: ...Mira Sport Attention Installer Caution Do not drill into buried cables or pipes Drill and plug the three holes using template Remove Cover and determine supply pipe position For back inlet use solder...

Page 13: ...wires are clear of all mounting holes Refit the Service Tunnel and Cover Make sure they fit correctly Do not overtighten screws Do not use alternative screws to secure the Cover This can cause intern...

Page 14: ...structions section before continuing COMMISSIONING Electrical supply is turned off at the mains Turn control to full cold Turn water supply fully on Check for water leaks Set control to LOW Switch on...

Page 15: ...Set control to HIGH _ The temperature will rise further Adjust temperature as required Flow rate will adjust automatically Press STOP button light on the button goes out Shower flow will continue for...

Page 16: ...r the lower the flow rate and vice versa _ _ _ Heated water is produced by adjusting the flow of cold water passed through a heater tank The shower has three heater settings How Your Electric Shower W...

Page 17: ...mperature across the range from hot to cold whilst also dealing with fluctuations in electrical and water supplies As a result there is a temperature limit the shower cannot go beyond For safety this...

Page 18: ...ired operating parameters refer to section Specifications _ For a cold shower select LOW For a summer warm shower select MEDIUM For a winter warm shower select HIGH During extremes of mains water supp...

Page 19: ...ew seconds before stopping Isolate power _ Switch on electrical supply Press START button Light on the button comes on Set to desired position Allow 10 15 seconds for any temperature adjustments to re...

Page 20: ...g possible electrical fault Switch on electrical s up p l y vi a the pullcord or wall mounted switch Renew the fuse or reset the MCB R C D I f f a u l t persists contact your installer S h o w e r cyc...

Page 21: ...icient water supply pressure for shut off Inlet valve faulty The minimum static pressure to ensure shut off and prevent dripping is 20 kPa 0 2 bar N o t e I f o t h e r appliances are operating static...

Page 22: ...r appliances whilst shower is in use Remove and clean Check case inserts are cut and fitted correctly Make sure electrical and plumbing services are not interfering with location Replace Replace Cons...

Page 23: ...will not turn off On On Off On Any Any InletValve Solenoid or Start Stop switch faulty Supply pressure below 20 kPa 0 2 bar R e p l a c e a s necessary Contact local water company Check mains water s...

Page 24: ...ross the flats of the metal connector Unscrew the filter using another wrench as shown Clean or renew the Filter as necessary Refit in reverse order making sure the Filter is screwed fully home Do not...

Page 25: ...25 DIMENSIONS 205 mm 85 mm 369 mm...

Page 26: ...240 V AC 1563 533 Thermostatic Valve Heater Tank 9 8 kW 240 V AC 1563 534 Outlet Connector Assembly 1563 536 Temperature Control Belt Thermostatic 1563 538 Temperature Cam Pulley 1563 540 Inlet Valve...

Page 27: ...switches A minimum air gap of 4 mm must be maintained between the connectors after assembly 405 58 406 27 416 38 1563 719 416 48 416 51 872 01 872 28 1563 532 1563 533 1563 538 1563 509 1563 543 A A...

Page 28: ...o a solid wall Everclear Showerhead White 2 1616 030 Chrome 2 1616 031 Mira s new Everclear range has been specially designed for hard water areas and reduces the risk of lime scale build up Logic Sho...

Page 29: ...ROWN BROWN BROWN BROWN RED RED RED GREEN GREEN BLUE Thermal Cutout Dual Disc L Solenoid Valve Pressure Power Selector Switch Low Flow Neon Start Stop Neon N Tank Connection Inlet Connector Internal Wi...

Page 30: ...30 NOTES...

Page 31: ...31 NOTES...

Page 32: ...e for a Service Technician to call If the performance of your product declines check in this manual to see if simple home maintenance is required If you require further assistance call our Customer Se...

Reviews: