20
The trouble shooting information tabled below gives details on probable causes and
remedies should difficulties be encountered whilst the shower is in operation.
Warning!
There are no user serviceable components beneath the cover of the
appliance.
Only a competent tradesperson should remove the front cover!
Symptom Power
Light
Low
Flow
Light
Heater
Low/
Med/
High
Probable Cause
Possible Remedy
A p p l i a n c e
f a i l s t o
operate.
Off
Off
Off
Off
Any
Any
Electrical supply
isolated at double
pole switch.
F u s e b l o w n o r
MCB/RCD tripped,
indicating possible
electrical fault.
Switch on electrical
s u p p l y v i a t h e
pullcord or wall
mounted switch.
Renew the fuse
or reset the MCB/
R C D . I f f a u l t
persists, contact
your installer.
S h o w e r
cycles from
hot to cold.
On
On
On
On
On
On
Off
Off
Med/
High
Med/
Hign
Med/
High
Med/
High
Handset blocked.
Water pressure
below minimum
r e q u i r e d f o r
a p p l i a n c e
operation.
Temperature dial or
heater setting too
high.
T h e r m o s t a t i c
mechanism is faulty
or damaged.
Remove and clean.
Make sure incoming
m a i n s w a t e r
stopcock and/or
appliance isolating
valve is fully turned
on.
Turn the heater
selector knob to
medium setting or
turn the temperature
control until a cooler
t e m p e r a t u r e i s
achieved.
Replace.
FAULT DIAGNOSIS