Mira Mode Maxim Installation And User Manual Download Page 3

5

4

1.  Installation of this product must be carried out in accordance 

with these instructions by qualified, competent personnel. Read 

all instructions before commencing installation.

2. 

The electrical installation must comply with BS 7671 (commonly 

referred  to  as  the  IEE  Wiring  Regulations)  and  all  relevant 

building regulations, or any particular regulation or practice 

specified by the local electricity supply company.

3.  The plumbing installation must comply with all national or local 

water  regulations  and  all  relevant  building  regulations,  or  any 

particular  regulation  or  practice  specified  by  the  local  water 

supply company.

4.  Isolate the electrical and water supplies before commencing 

installation.  Mains  connections  are  exposed  when  the  valve 

module cover is removed.

5. 

The  valve  module  must  be  earthed,  ensure  supplementary 

bonding is provided in accordance with the wiring regulations.

6. 

The valve module must be permanently connected to a 3A fused 

connection unit and be provided with means for disconnection 

incorporated  in  the  fixed  wiring  in  accordance  with  the  wiring 

regulations.

7. 

We strongly recommend that a 30mA RCD is included in the 

electrical supply to the valve module.

8. 

DO NOT

  install  the  valve  module,  controller  or  the  On/

Off Remote Button in areas with high humidity and temperature 

(i.e. steam rooms and saunas).

9. 

DO NOT

 install the valve module or fittings where they may be 

exposed to freezing conditions. Ensure that any pipework that 

could become frozen is properly insulated.

10. 

DO NOT

 perform any unspecified modifications, drill or cut holes 

in the product other than instructed by this guide. When servicing 

only use genuine Mira Showers replacement parts.

11. 

DO NOT

 operate the product if water is leaking from inside the 

valve module. Isolate electrical and water supplies to the product 

and refer to the fault diagnosis section.

12. 

DO NOT

 apply power to the product if it is thought to have been 

exposed to freezing conditions. Isolate electrical and water 

supplies to the product and contact Kohler Mira Ltd.

13. 

DO NOT

 allow children to play with the product.

14. 

DO NOT

 allow children to clean or perform any user maintenance 

without supervision.

15. 

DO NOT

 remotely operate or alter any of the Mira Mode Maxim 

shower settings if it is already occupied and / or being used by 

another person.

16. 

If the valve module is dismantled during installation or servicing 

then, upon completion, an inspection must be made to ensure 

all electrical connections are secure and that there are no leaks.

17. Make sure that you fully understand how to operate this shower 

and make sure that it is properly maintained in accordance with 

the instructions given in this manual.

Important Safety Information

Products manufactured by Kohler Mira Ltd. are designed to be safe, provided that they are 

installed, used and maintained in good working order, in accordance with our instructions 

and recommendations. Follow all warnings, cautions and instructions contained in this guide, 

and on, or inside the product. Failure to follow the instructions provided with this product 

will invalidate the guarantee.

Warning! To reduce the risk of fire, electric shock or injury please read the important 

information listed below.

Summary of Contents for Mode Maxim

Page 1: ...rantee on any replacement parts or product ends at the original expiry date For shower fittings or consumable items we reserve the right to supply replacement parts only What is Not Covered Call out c...

Page 2: ...on videos datasheets or spares information please visit the Mira Showers website Contents Important Safety Information 4 Guarantee 6 Recommended Usage 6 Pack Contents 7 Specifications 12 General insta...

Page 3: ...DO NOT perform any unspecified modifications drill or cut holes in the product other than instructed by this guide When servicing only use genuine Mira Showers replacement parts 11 DO NOT operate the...

Page 4: ...fittings must provide a minimum air gap of 25mm between the handshower and the spill over level of any bath shower tray or basin There must be a minimum distance of 30mm between the handshower and th...

Page 5: ...m Screws 2 x 70 mm Screws 1 x Slide Bar Assembly 1 x Handset 1 x Component Pack 1 x Hex Key 2 x Hex Screws 2 x Brackets 1 x Hose 2 x Rubber Washers 3 x Wall Plugs 3 x Fixings Screws 1 x Component Pack...

Page 6: ...Assembly 1 x Rain Core 1 x Core Removal Tool 1 x Chrome Supply Tube 1 x Ceiling Mount Plate Assembly 1 x Shower Arm 1 x Concealing Shroud 1 x Deluge Head 2 x Wall Plugs 2 x Fixing Screws 1 x Cable 1 x...

Page 7: ...conditions Ambient Temperature 1 C 40 C Maximum Relative Humidity 95 non condensing Flow Rates Nominal Flow Rate Valve capable of up to 16 l min 1 bar Electrical Supply Voltage 230V ac 50 Hz Maximum L...

Page 8: ...ose to the Digital Mixing Valve for ease of maintenance Caution Risk of product and property damage The Digital Mixing Valve must be installed in a dry ventilated area where it will not freeze The sho...

Page 9: ...tem Boiler Rating 24 kW 80 000 Btu h 30 kW 100 000 Btu h 36 kW 120 000 Btu h Flow Regulator 7 litres min 9 litres min Not required Colour White Green White Orange N A 1 Unscrew hot inlet plastic nuts...

Page 10: ...where Bluetooth communication with the Digital Mixer Valve is poor e g mixer valve installed under metal bath in front of metal cistern on foil backed plasterboard Water supply pipes must be flushed p...

Page 11: ...ion with the fixing screws supplied Caution Risk of product damage Make sure both hot and cold supply pipes are flushed thoroughly prior to connection to the Digital Mixing Valve Any product malfuncti...

Page 12: ...he Controller in the backplate and press down on the bottom button as you install in position Installation Controller 1 3 4 5 For solid walls drill the fixing holes for the backplate with a 6mm drill...

Page 13: ...itment before removing the tape This will ensure that there is no clearance issue Installation On Off Remote Button 1 3 Route the cable from the digital valve through the hole in the wall Note Make su...

Page 14: ...are as follows Fix at convenient height for all the family Position the fittings so that water sprays down the centre of the bath or away from the opening of a shower cubicle Water should spray away...

Page 15: ...assembly Note Do not fit the handshower until after pipework has been fully flushed through Refer to Commissioning b Fit the shower hose to the handset Make sure that you fit the shower hose and flow...

Page 16: ...cutter to cut the pipe to the desired length Note Cut the brass pipe at least 75mm above the ceiling mount plate to allow room to fit the olive nut and elbow 4 Offer the chrome shroud to the brass pip...

Page 17: ...ittings Suitable for solid dry lined stud partition shower cubicle or laminated panel walls Plan installation location of the handshower and deluge showerhead before installing fittings kit Note Make...

Page 18: ...osition of the fixing hole in the top support 2 6 4 5 Drill the fixing holes fit the wall plugs and secure the backplate to the wall with two fixing screws 3 Drill the fixing hole for the top support...

Page 19: ...e Head Fix at convenient height for all users Position so that water sprays down the centre of the bath or away from the opening of a shower cubicle Make sure that the water sprays away from the Contr...

Page 20: ...Press the button to turn the shower on and reduce temperature to full cold For Low Pressure pumped version let shower run in order to prime the pump For long pipe runs allow 3 4 minutes for priming C...

Page 21: ...p half for 10 Seconds approx until the Temperature Indicator light pulses on off Note After 5 seconds the lights will pulse to indicate pairing mode you need to continue to hold the button for the ent...

Page 22: ...itable for Pumped Gravity water systems Refer to Typical Installations No power to Digital Mixing Valve Check electrical connection and power supply Inlet water supply isolators not fully turned on Ch...

Page 23: ...alve only Refer to Use of Flow Regulators for correct operation Outlet pipe run is too long Ensure outlet pipe work is thermally lagged Symptoms Probable Cause Possible Remedy Showering temperature to...

Page 24: ...s Mira Mode Showering App corrupted Delete the Mira Mode showering App reboot the mobile phone and re install the Mira Mode showering App No Lights on interface Not connected to valve Check all cables...

Page 25: ...ccess to the checkvalve cartridges and filters Use a flat blade screwdriver to carefully lever the cartridges out Remove the filters and clean or renew Refit seals pipes and plastic nuts Plastic nuts...

Page 26: ...50 Notes...

Reviews: