Mira Mode Maxim Installation And User Manual Download Page 10

19

18

Key to Installation Schematic

Description

A

Electrical Cable from the Controller to the Valve - 9.5 metres

B

On/Off Remote Button cable from the On/Off Remote Button to the Valve - 9.5 metres

C

On/Off Remote Button - placed outside of the enclosure

D

Controller

E

Coupler Cable - for connection between the valve and the remote lead and/or the 

Controller

F

Digital Mixing Valve

G

Mira Mode Maxim Ceiling Fed shower fittings - Rear Fed options are available

H

Deluge showerhead

J

3 AMP Switched Fused Spur - Outside of the bathroom - enables you to isolate the shower. 

Should be easily accessible for resetting product.

Important Installation Considerations 

• 

Ensure Pumped for Gravity showers are not connected to any mains water pressure 

e.g. stored gravity hot water and cold mains water.

• 

High Pressure/Combi Valves should not be fitted to a Pumped Gravity System.

• 

The Digital Mixing Valve should not be installed where it can become frozen or be subjected 

to ambient temperatures in excess of 40ºC.

• 

 Position the Digital Mixing Valve so that there is enough room for maintenance (e.g. 

removal of the valve lid) and make sure safe and easy access is available at all times.

• 

Installing the Digital Mixing Valve onto shared water supplies may reduce its flow 

performance.

• 

Avoid installations where air locking could occur.

•   Cold water cisterns should hold no less than 230 litres and Hot water cylinders no less 

than 210 litres. (Gravity system only).

• 

 Your water supply system must be capable of delivering up to 16 l/min mixed water.

• 

Ensure water supply temperatures are within specification. Hot water 55˚C to 65˚C, Cold 

water 1˚C to 20˚C.

• 

To reduce any effects of water hammer secure all pipe work rigidly.

• 

Do not fit the valve in a position where Bluetooth

®

 communication with the Digital Mixer Valve 

is poor e.g. mixer valve installed under metal bath, in front of metal cistern, on foil backed 

plasterboard.

• 

Water supply pipes must be flushed prior to connecting the mixing valve to the system 

so debris cannot enter the mixing valve internals.

•  Fully commission the product after installation taking care to look for any leaks and 

correct operation.

General Installation Requirements

The installation must be carried out in accordance with these instructions, and must be 

conducted by designated, qualified and competent personnel.

A separate, permanently connected supply must be taken from the ring main to the appliance 

through a 3 AMP double pole switched fused spur providing a minimum 3mm contact 

separation gap in each pole.

The use of supply-line or zone strainers will reduce the need to remove debris at the 

Digital Mixer Valve. The recommended maximum mesh aperture dimension for such 

strainers is 0.5mm.

Pipework must be rigidly supported to avoid any strain on the connections.
Long outlet pipework (dead-legs) should be kept to a minimum to avoid temperature fluctuations.
Supply pipework layout must be arranged to minimize the effect of other outlet usage upon 

the dynamic pressures at the Digital Mixing Valve inlets.
To eliminate pipe debris it is essential that supply pipes are thoroughly flushed through before 

connection to the Digital Mixing Valve.
Cables routed through wall cavities, chased into solid walls, directed under baths or in 

attic spaces must be fitted in such a way that they can later be removed. To facilitate this 

appropriate cable conduit/trunking must be used at all times. The conduit/trunking must be 

at least 20mm diameter/square to allow for the safe removal of the connectors.
Failure to do so may result in an inability to carry out any maintenance or service. Safe and 

easy access to the product should be available at all times.

Summary of Contents for Mode Maxim

Page 1: ...rantee on any replacement parts or product ends at the original expiry date For shower fittings or consumable items we reserve the right to supply replacement parts only What is Not Covered Call out c...

Page 2: ...on videos datasheets or spares information please visit the Mira Showers website Contents Important Safety Information 4 Guarantee 6 Recommended Usage 6 Pack Contents 7 Specifications 12 General insta...

Page 3: ...DO NOT perform any unspecified modifications drill or cut holes in the product other than instructed by this guide When servicing only use genuine Mira Showers replacement parts 11 DO NOT operate the...

Page 4: ...fittings must provide a minimum air gap of 25mm between the handshower and the spill over level of any bath shower tray or basin There must be a minimum distance of 30mm between the handshower and th...

Page 5: ...m Screws 2 x 70 mm Screws 1 x Slide Bar Assembly 1 x Handset 1 x Component Pack 1 x Hex Key 2 x Hex Screws 2 x Brackets 1 x Hose 2 x Rubber Washers 3 x Wall Plugs 3 x Fixings Screws 1 x Component Pack...

Page 6: ...Assembly 1 x Rain Core 1 x Core Removal Tool 1 x Chrome Supply Tube 1 x Ceiling Mount Plate Assembly 1 x Shower Arm 1 x Concealing Shroud 1 x Deluge Head 2 x Wall Plugs 2 x Fixing Screws 1 x Cable 1 x...

Page 7: ...conditions Ambient Temperature 1 C 40 C Maximum Relative Humidity 95 non condensing Flow Rates Nominal Flow Rate Valve capable of up to 16 l min 1 bar Electrical Supply Voltage 230V ac 50 Hz Maximum L...

Page 8: ...ose to the Digital Mixing Valve for ease of maintenance Caution Risk of product and property damage The Digital Mixing Valve must be installed in a dry ventilated area where it will not freeze The sho...

Page 9: ...tem Boiler Rating 24 kW 80 000 Btu h 30 kW 100 000 Btu h 36 kW 120 000 Btu h Flow Regulator 7 litres min 9 litres min Not required Colour White Green White Orange N A 1 Unscrew hot inlet plastic nuts...

Page 10: ...where Bluetooth communication with the Digital Mixer Valve is poor e g mixer valve installed under metal bath in front of metal cistern on foil backed plasterboard Water supply pipes must be flushed p...

Page 11: ...ion with the fixing screws supplied Caution Risk of product damage Make sure both hot and cold supply pipes are flushed thoroughly prior to connection to the Digital Mixing Valve Any product malfuncti...

Page 12: ...he Controller in the backplate and press down on the bottom button as you install in position Installation Controller 1 3 4 5 For solid walls drill the fixing holes for the backplate with a 6mm drill...

Page 13: ...itment before removing the tape This will ensure that there is no clearance issue Installation On Off Remote Button 1 3 Route the cable from the digital valve through the hole in the wall Note Make su...

Page 14: ...are as follows Fix at convenient height for all the family Position the fittings so that water sprays down the centre of the bath or away from the opening of a shower cubicle Water should spray away...

Page 15: ...assembly Note Do not fit the handshower until after pipework has been fully flushed through Refer to Commissioning b Fit the shower hose to the handset Make sure that you fit the shower hose and flow...

Page 16: ...cutter to cut the pipe to the desired length Note Cut the brass pipe at least 75mm above the ceiling mount plate to allow room to fit the olive nut and elbow 4 Offer the chrome shroud to the brass pip...

Page 17: ...ittings Suitable for solid dry lined stud partition shower cubicle or laminated panel walls Plan installation location of the handshower and deluge showerhead before installing fittings kit Note Make...

Page 18: ...osition of the fixing hole in the top support 2 6 4 5 Drill the fixing holes fit the wall plugs and secure the backplate to the wall with two fixing screws 3 Drill the fixing hole for the top support...

Page 19: ...e Head Fix at convenient height for all users Position so that water sprays down the centre of the bath or away from the opening of a shower cubicle Make sure that the water sprays away from the Contr...

Page 20: ...Press the button to turn the shower on and reduce temperature to full cold For Low Pressure pumped version let shower run in order to prime the pump For long pipe runs allow 3 4 minutes for priming C...

Page 21: ...p half for 10 Seconds approx until the Temperature Indicator light pulses on off Note After 5 seconds the lights will pulse to indicate pairing mode you need to continue to hold the button for the ent...

Page 22: ...itable for Pumped Gravity water systems Refer to Typical Installations No power to Digital Mixing Valve Check electrical connection and power supply Inlet water supply isolators not fully turned on Ch...

Page 23: ...alve only Refer to Use of Flow Regulators for correct operation Outlet pipe run is too long Ensure outlet pipe work is thermally lagged Symptoms Probable Cause Possible Remedy Showering temperature to...

Page 24: ...s Mira Mode Showering App corrupted Delete the Mira Mode showering App reboot the mobile phone and re install the Mira Mode showering App No Lights on interface Not connected to valve Check all cables...

Page 25: ...ccess to the checkvalve cartridges and filters Use a flat blade screwdriver to carefully lever the cartridges out Remove the filters and clean or renew Refit seals pipes and plastic nuts Plastic nuts...

Page 26: ...50 Notes...

Reviews: