![Mira Element Thermostatic Mixer Installation And User Manual Download Page 19](http://html1.mh-extra.com/html/mira/element-thermostatic-mixer/element-thermostatic-mixer_installation-and-user-manual_1804999019.webp)
19
Built-in Thermostatic Mixer
1. solid Wall or stud Partition
(using securing Brackets - Mounting off Front Face of Wall)
outlet Pipe Bir
outlet Pipe BiV
outlet Pipe BiV
cold inlet
hot inlet
thermostatic
Mixer
alternative Pipe
layouts
62 mm Min
24 mm Max
Finished Wall
6 mm Min
Finished Wall
Finished Wall
surface
1.1
Determine the route for the hot and
cold supply pipework and for the
outlet pipework. When connecting
to the BiV shower Fittings it is
recommended that the outlet be
positioned above and to one side
of the Mixer. this is to prevent the
Flexible hose from obstructing the
shower controls.
1.2
remove the two shroud screws
(retain for later use) and remove the
Mixer from the Building-in shroud.
1.3
Determine the position of the Mixer
and draw around the Building-in
shroud.
1.4
Mark the routes for the hot and cold
supply pipework at 108 mm centres
(
Hot - Left, Cold - Right
).
Falling supplies:
For falling supplies
loosen the Grubscrew on each Elbow
using the 2.5 mm hexagon Key
(supplied). remove the Elbows and
install on opposite sides. retighten
the Grubscrews.
Caution!
Do not overtighten.
note!
Make sure that the ‘o’ seals
are correctly fitted and that the
Filter Plugs are positioned to the
front (i.e. hexagonal Key facing
forward).
1.5
Mark the route for the outlet
pipework.
note!
the outlet Elbow should be
sited above the Mixer and on the right
or left, as site dictates.
1.6
remove the plasterboard and/or
brick work to a minimum depth of
62 mm.
securing
Bracket