16
1.6
loosen the Grubscrew with the 2.5 mm hexagon Key (supplied) and remove
the Backplate from the Mixer.
1.7
secure the Backplate to the wall using the screws (supplied).
1.8
Fit the concealing Plates.
note!
Apply silicone sealant to the back face of the flange.
Caution!
it is essential at this point that the supply pipework is thoroughly
flushed through before connection to the Mixer. Failure to do so may result in
product malfunction.
1.9
Fit the compression nuts and olives onto the pipework.
1.10
Align the Mixer with the pipework and fit onto the Backplate.
1.11
tighten the compression nuts onto the Mixer with a suitable spanner.
Caution!
take care not to damage the chrome surfaces.
1.12
tighten the Grubscrew to secure the Mixer to the Backplate.
1.13
Fit the
shower Fittings
, refer to your shower Fittings installation and User
Guide for instructions.
note!
For high pressure systems, a 12 litre/minute Flow regulator (supplied)
can be fitted under the Hose Washer (refer to illustration).
1.14
turn on the hot and cold water supplies and check for leaks.
1.15
Before using the shower, refer to section:
‘Commissioning’
.
Flow regulator
(for high pressure
systems)
Grubscrew
Hot
Cold