5. ADJUSTMENT
5-1. Adjustment of Image Registration
After the Mechanical Control Board (PWB-A) is replaced, print an image sample. If the
starting position of the image (registration gap (d)=4mm) in the sub-scanning direction is
not suitable, adjust the gap by following one of the procedures described below.
1
Remove the right cover so that VR1 of PWB-A can be adjusted.
2
Turning VR1 on PWB-A in the clockwise direction makes the gap (d) greater and
turning it in the counter-clockwise direction makes the gap (d) smaller.
Adjustment by Voltage
1
Touch the positive and negative terminals of the tester to VR1 and frame GND respec-
tively with power turned on.
2
Adjust VR1 until the tester reads between 2.4 to 2.54 VDC.
VR1
d
4mm