background image

M-Box

 Manual

     

6

GENERAL

 

SAFETY

 

∆ DO NOT expose vibrator to rain.

 

∆ DO NOT use vibrator motor in damp or wet 

locations without proper electrical circuits.

 

∆ DO NOT immerse the motor part in con-

crete.

 

∆ ALWAYS keep clear of rotating or moving 

parts while operating.

 

∆ NEVER leave the machine unattended while 

running

 

∆ ALWAYS disconnect the motor from the 

power source when not in use, before servic-

ing, and when changing flexible shafting and 
vibrator heads.

 

∆ Allow the machine to cool 

before servicing. Contact with 

hot components can cause 

serious burns.

 

∆ Before Each use, ALWAYS check the motor 

to make certain that there are no damaged 

parts and that all parts function properly. 

If any damage or malfunctioning parts are 

found, have them repaired or replaced by an 

authorized service facility.

 

∆ ALWAYS secure forms. Make sure the form 

work is well made and braced to withstand 

the stresses made by vibration.

 

∆ ALWAYS keep vibrator motor clean for bet-

ter and safer operation.

 

∆ ALWAYS store equipment properly when 

it is not being used. Equipment should be 

stored in a clean, dry location out of reach 

of children and unauthorized personnel.

 

∆ Use only factory authorized replacement 

parts.

 

∆ Store idle vibrator motor. When not in use, 

motor should be stored in a dry, safe stor-

age area.

ELECTRICAL SAFETY

 

∆ Power tools must match the outlet. NEVER 

modify the plug in any way. DO NOT use the 

adapter plugs with earthed (grounded) power 

tools. Unmodified plugs and matching outlets 

will reduce risk of electric shock.

 

∆ Avoid contact with earthed or grounded 

surfaces such as pipes, radiators ranges and re-

frigerators. There is an increase risk of electric 

shock if your body is earthed or grounded.

 

∆ DO NOT expose power tools to rain or wet 

conditions. Water entering a power tool will 

increase risk of electric shock.

 

∆ DO NOT abuse power cord. NEVER use the 

cord for carrying, pulling or unplugging the 

power tool. Keep cord away from heat, oil 

sharp edges or moving parts. Damaged or 

entangled cords increase the risk of electric 

shock.

 

∆ When operating a power tool outside use an 

extension cord suitable for outdoor use. Use of 

a cord suitable for outdoor use reduces the risk 

of electric shock.

 

∆ This unit is double-insulated. The double in-

sulation between the electric-conducting part 

and the outside frame makes grounding un-

necessary. However, if parts are replaced with 

wrong parts or assembled incorrectly, the ma-

chine may become unsafe to operate. Use only 

Minnich Recommended replacement parts.

 

∆ When applicable, use a protection wiring de-

vice such as a Ground Fault Circuit Interrupter, 

for the protection of personnel.

 

∆ Operate electric motor only at the specific volt-

age indicated on the nameplate.

 

∆ DO NOT spray water onto electric motor.

 

∆ DO NOT yank the cord to disconnect it from 

the receptacle. Grasp the plus itself to discon-

nect it.

 

∆ ALWAYS make sure the ON/OFF switch is in the 

OFF position hen not in use, and before insert-

ing the power plug into an AC  replacement.

 

∆ Before plugging the motor into a power source, 

ALWAYS remove any wrenches or other tools 

from the motor, shaft, and head that were used 

for assembly.

Summary of Contents for M-BOX

Page 1: ...Minnich M BOX Minnich Manufacturing 1444 ST RT 42 Mansfield OH 44903 Contact Phone 419 903 0010 Email sales minnich mfg com ...

Page 2: ...ures only If there are any questions regarding the ma chine or its application which are not covered in this manual or in other literature accompa nying this unit please contact your Minnich Dealer or Minnich Manufacturing at 419 903 0010 or sales minnich mfg com It is Minnich s policy to constantly strive to improve our products The information spec ifications and illustrations in this publicatio...

Page 3: ...ifornia and some author ities have listed repairable crystalline silica as a substance known to cause cancer When cutting such materials always follow the respiratory precautions mentioned above RESPIRATORY HAZARDS Grinding cutting drilling of masonry concrete metal and fumes containing chemicals known to cause serious or fatal injury or illness such as respirato ry disease cancer birth defects or...

Page 4: ...al hazards that could injure you or others The safety messages specif ically address the level of exposure to the opera tor and are preceded by one of four words DANGER WARNING NOTICE or NOTICE Do not operate or service the equipment before reading the entire manual Safety precautions should be followed at all times when operating this equipment Failure to read and understand the safe ty messages ...

Page 5: ...ne should be made only by the manufacturer who shall confirm that the machine is in comfortability with appropriate safety regulations Never use accessories or attachments that are not recommended by Minnich for the equip ment Damage to the equipment and or injury to user may result Always know the location of the nearest fire extinguisher ALWAYS know the location of the nearest first aid kit ALWA...

Page 6: ...outlets will reduce risk of electric shock Avoid contact with earthed or grounded surfaces such as pipes radiators ranges and re frigerators There is an increase risk of electric shock if your body is earthed or grounded DO NOT expose power tools to rain or wet conditions Water entering a power tool will increase risk of electric shock DO NOT abuse power cord NEVER use the cord for carrying pullin...

Page 7: ...rous and must be repaired Disconnect the plug from the power cord source and or the battery pack from the power tool before making any adjustments chang ing accessories or storing power tools Such preventative safety measures reduce the risk of starting the power tool accidentally Store idle power tools out of reach of chil dren and do not allow persons unfamiliar with the power tool or these inst...

Page 8: ...issioning is a controlled process used to safety retire a piece of equipment that is no longer serviceable If the equipment poses an unaccept able and unrepairable safety risk due to wear or damage or is no longer cost effective to maintain beyond life cycle reliability and is to be decommis sioned demolition and dismantlement be sure to follow rules below ALWAYS observe all applicable compulsory ...

Page 9: ...ust be preformed only by qual ified repair personnel Service or maintained preformed by unqualified personnel could result in injury or death When servicing a tool use only identical replacement parts Use of unauthorized parts may create a risk of injury or death ELECTRICAL SAFETY Turn generator OFF before preforming main tenace on the generator or making contact with the output receptables NEVER ...

Page 10: ...ox Manual 10 GENERAL SPECIFICATION M BOX INPUT SOURCE OUTPUT source Volts 230 230 Phase Single Three Hertz 50 60 Hz 6 000 VPM 8 000 VPM 10 000 VPM 10 800 VPM Amps 15 Minimum 10 5 Maximum 100Hz 133Hz 180Hz ...

Page 11: ...LUGGED Input From Power Source 230 Volt AC Single Phase 50 60 Hz 15 Amps Minimum 419 903 0010 www minnich mfg com VOLTS MODEL CYCLE PHASE SERIAL VPM M BOX 180 6000 8000 10 800 230 AC 3 CAUTION Hazard of electrical shock burn or explosion Turn off power supplying this equipment before working on or inside Replace cover before re energizing WARNING If this unit is subjected to an excessive shock by ...

Page 12: ...king on or inside Replace cover before re energizing WARNING If this unit is subjected to an excessive shock by being dropped or impacted or if the enclosure is damaged it should be disconnected and not used until it has been inspected and repaired by a qualified electrician or personnel PRIOR TO OPERATION Read and understand all safety operating and maintenance instructions before using this prod...

Page 13: ...enance instructions before using this product O F F 6 000 8 000 10 8 0 0 O F F 6 000 8 000 10 8 0 0 419 903 0010 www minnich mfg com COMPONENTS MAY BE ENERGIZED EVEN AFTER BEING UNPLUGGED Input From Power Source 230 Volt AC Single Phase 50 60 Hz 15 Amps Minimum 419 903 0010 www minnich mfg com VOLTS MODEL CYCLE PHASE SERIAL VPM M BOX 180 6000 8000 10 800 230 AC 3 CAUTION Hazard of electrical shock...

Page 14: ... the OFF position Unplug the M Box plug from the portable Gen erator Source Starting Procedures Always shut off the vibrators at the vibrator switch instead of the X box Switch Con trolling on off switching at box may lead to unintended start of the vibrator units The M box converter is designed to run 2 individual 230v 3phase concrete vibrators with 100 feet of extension cord on each unit The box...

Page 15: ...15 M BOX Manual NOTES ...

Page 16: ... or otherwise NO EXPRESS WARRANTIES AND NO IMPLIED WARRANTIES WHETHER OF MERCHANTABI LITY OR FITNESS FOR ANY PARTICULAR PURPOSE OR WEAR CAPACITY OR OTHERWISE SHALL APPLY TO THE GOODS AND SERVICES SUPPLIER SPECIFICALLY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS AND IMPLIED WARRANTIES NO WAIVER ALTERATION ADDITION OR MODIFICATION OF THE FOREGOING SHALL BE VALID UNLESS MADE IN WRITING AND SIGNED BY AN ...

Page 17: ...r Parts Print specific information If you don t have a login give us a call Contact us at 419 903 0010 Contact Minnich Manufacturing through the following num ber to locate a dealer near you 419 903 0010 NON DEALER AND INTERNATIONAL COSTUMERS All orders are treated as Standard Orders and will ship the same day if received prior to 3PM EST Scan for Helpful Videos ...

Reviews: