5
F
ILTER
D
ESIGN
T he Filter Design tab shows sets of graphs for the various channels. Click on the tabs at the right to display the
response graphs for different sets of channels (left and right, center, subwoofer, and surrounds, in the case of
5.1 and 7.1 systems). For each set of graphs, a number of variants can individually be turned on and off with the
checkboxes above the graphs.
Avg. spectrum (before)
The average of the measured magnitude responses. These plots are shown in light blue.
Avg. spectrum (after)
The predicted average magnitude response after correction. These plots are shown in green, and
can be viewed only after filters have been generated with the Optimize button.
Target
The target curve – that is, the desired in-room magnitude response. This curve is user-adjustable
so you can fine-tune it to best suit your speakers, room, and preferences. See
All (before)
All of the measured magnitude responses. These plots are shown dark blue.
All (after)
All of the predicted magnitude responses after correction. These plots are shown in dark green,
and can be viewed only after filters have been generated with the Optimize button.