SMART CAT5 SWITCH 16 IP
.
IPMI over Serial
- If your host system supports IPMI V1.5 and has an Intel EMP
(Emergency Management Port, usually COM2) connector, you can connect IPMI
through serial port 1 on Smart 16 IP. Please note:
•
Set the EMP port to Always enable and switch off the Restricted Mode.
•
The BMC should accept a null username and a non-null password
account as login.
59.
•
Passwords are 4 -16 characters long.
•
Use a null modem cable for connection
IPMI over LAN
- You can connect the IPMI over a LAN connection. You need a
host system with IPMI V1.5 and a network adapter with a sideband connection to
the BMC (mostly on board). In the IPMI Settings, enter the IP-address of this host
system and the correct password for the LAN connection.
You can also access other IPMI systems when you enter their IP address.
LDAP Settings
You can keep authentication information in a central LDAP directory.
From the Smart 16 IP Menu choose LDAP Settings. The LDAP Settings appears.
See Figure 29.
Figure 29 LDAP Settings
User LDAP Server
- Enter the name or IP address of the LDAP server containing
all the user entries. If you use a name, configure a DNS server in the network
settings.
Base DN of User LDAP Server
- Specify the distinguished name (DN) where the
directory tree starts in the user LDAP server.
Type of external LDAP Server
- Set the type of the external LDAP server. This
is necessary since some server types require special handling. Also the default