Default is 1pcs.
BAL_VCELL_MIN[V]
Balancing is allowed if cell voltages are
above this value.
Default is 3V
BAL_VCELL_DIFF_START [V]
If the voltage difference between cells
exceeds this value start balancing the
cells.
Default is 70mV.
BAL_VCELL_DIFF_STOP[V]
If the voltage difference between cells is
less than this value stop balancing the
cells.
Default is 40mV.
OUT_VOLTAGE[V]
The output voltage.
Default is 12V.
OUT_FREQUENCY[kHz]
The working frequency of the output
buck-boost converter.
Default 300kHz
OUT_MAX_REGULATOR_STEP[nr]
Maximum allowed regulation step number
for output module (0-255)
Default 100.
MOB_ONOFF_TOUT[ms]
The power switch on the motherboard(if
connected) will be shorted this period to
turn the Motherboard ON or OFF
Default is 500ms
POUT_LO[W]
Output power low threshold for
motherboard alive sensing. If output
power is lower than this threshold shut
down impulse will NOT be sent to the
motherboard when shut down conditions
are fullfilled.
Default is 2W.
POUT_HI[W]
Output power high threshold for
motherboard alive sensing. If output
power is higher than this threshold shut
down impulse can be sent to the
motherboard when shut down conditions
are fullfilled.
Default is 6W.
OCV_SOC0
Open Circuit Voltage State Of Charge
detection for initial 0% fuel gauge
estimation.
Default is 11.8V
OCV_SOC10
Open Circuit Voltage State Of Charge
detection for initial 10% fuel gauge
estimation.
Default is 11.9V