User Manual of DH-300/400 Full Automatic Soldering Robot
34
OK
To execute the reset operation during function setting operation:
Reset (Cancel the current operation and return)
5.
XY-axis idling speed setting:
Operation process:
Function
X→: Select the function No. 5
OK (Enter)
X←, X→, Y↑, Y↓, Z↑, Z↓: Adjust
the
parameter
(1-800);
1
represents the minimum speed in
mm/s, and 800 represents the
maximum
speed
in
mm/s.
Wherein, the increment of X
button is 1mm/s, the increment of
Y button is 10mm/s, and the
increment of Z button is 100mm/s.
Display status of nixie tube:
Display the function item number
Before adjustment
After adjustment
OK
To execute the reset operation during function setting operation:
Reset (Cancel the current operation and return)
6.
Z-axis idling speed setting:
Operation process:
Function
X→: Select the function No. 6