3
ERR LED (red)
State Description
Off
Off or operating
Blinks once
Error counter reached or exceeded preset value
Flickering
Automatically detecting baud rate
Blinks twice
NMT slave or NMT master detected a Heartbeat event
(Heartbeat consumer)
Lit Bus
off
3. Connections
3-1. Interface Connector Pin Arrangement
Refer to "2-1. Rear Panel CANopen Interface."
3-2. Cable Length
The relationship between the baud rate and overall cable length is as shown below.
Baud rate
Overall length
10 kbps
Up to 1,000 m
20 kbps
Up to 1,000 m
50 kbps
Up to 1,000 m
100 kbps
Up to 600 m
125 kbps
Up to 500 m
250 kbps
Up to 250 m
500 kbps
Up to 100 m
800 kbps
Up to 50 m
1 Mbps
Up to 25 m
3-3. Connection Precautions
Always turn off the power before connecting wires.
Do not turn on the power until all installation work is complete. This device lacks a dedicated power
on/off switch.
Where possible, keep the cables connected to the device away from noise sources such as motor
power lines and control I/O units.
Always ground the device. Ground using a Class D independent ground. Do not use a ground
shared with motor power supplies.
Turn on the terminating resistance for the CANopen connector farthest from the PLC.
Use a dedicated CANopen connector cable.
Use a connector cable meeting specifications for CiA DR-303-1.