31
7
.
Specifications of interface
7-1.
Specifications of CC-Link
interface
Specifications Contents
Version Ver.1.10
The number of occupied stations
Selectable from 1, 2 or 4 stations.
Communication method
Polling method
Synchronous method
Bit synchronization method
Baud rate
Selectable from 156 k, 625 k, 2.5 M, 5 M and 10 Mbps
Transmission path form
RS485 bus
Transmission format
HDLC conforming
Remote station number
In the case of 1 station occupied, No's.01 to 64 can be
selectable.
In the case of 2 stations occupied, No's.01 to 63 can be selectable.
In the case of 4 stations occupied, No's.01 to 61 can be selectable.
Numbers of connection
In the case of 1 station occupied, 64 units at maximum.
In the case of 2 stations occupied, 32 units at maximum.
In the case of 4 stations occupied, 16units at maximum.
Termination
Resistance externally attached.
Status LED
RUN, ERR
7-2.
Accessories
CC-Link
Instruction Manual
1
piece
CC-Link
communication connector
1 piece
※
Attached to main body.
(MSTB 2,5-ST-5,08 ABGY AU by PHOENIX CONTACT)