22
•
2 stations occupied
Device No.
Contents Classification
RXn0
①
Setting value writing request (Response 1)
Communication
RXn1
RXn2
②
General command response (Response 2)
RXn3
③
Writing/reading out selection response (R/W response)
RXn4
④
Operation mode changeover response(Response 3)
RXn5
RXn6
⑤
CPU normal operation
RXn7
RXn8
⑥
Decimal point position 1
RXn9
⑥
Decimal point position 2
RXnA
⑥
Decimal point position 4
RXnB
RXnC
RXnD
RXnE
RXnF
RX(n+1)0
⑦
Near Zero
Control output
RX(n+1)1
⑦
F.Flow/S1
RX(n+1)2
⑦
M.Flow/S2
RX(n+1)3
⑦
D.Flow/S3
RX(n+1)4
⑦
Over/S4
RX(n+1)5
⑦
OK
RX(n+1)6
⑦
Under
RX(n+1)7
⑦
Stable
RX(n+1)8
⑦
Finish
RX(n+1)9
⑧
Weighing value over
RX(n+1)A
⑨
During hold
RX(n+1)B
⑦
Full
RX(n+1)C
RX(n+1)D
⑩
Discharge (Gate open)
RX(n+1)E
⑪
Sequence error
RX(n+1)F
⑫
Abnormal weight
RX(n+2)0
⑬
Brand number
10
0
1
RX(n+2)1 2
RX(n+2)2 4
RX(n+2)3 8
RX(n+2)4
10
1
10
RX(n+2)5 20
RX(n+2)6 40
RX(n+2)7 80
~
RX(n+3)0
System reservation zone
RX(n+3)1
RX(n+3)2
RX(n+3)3
RX(n+3)4
RX(n+3)5
RX(n+3)6
RX(n+3)7
RX(n+3)8
RX(n+3)9
⑭
Initialed data setting complete flag
RX(n+3)A
⑮
Error condition flag
RX(n+3)B
⑯
Remote READY
RX(n+3)C
RX(n+3)D
RX(n+3)E
RX(n+3)F
n : Value decided by setting of station No.