13
1
Net weight value(4 stations ,2 stations )
Area for displaying the net weight value
Data type
:
32 bits binary with + or
−
Range of setting value
:−
99 999
〜
99 999
2
Gross weight value(4 stations )
Area for displaying the gross weight value
Data type
:
32 bits binary with s+ or
−
Range of setting value
:−
99 999
〜
99 999
3
Error code(4 stations ,2 stations ,1 station )
Refer to below table of
④
error assistance code too.
Area for displaying the error No. generating in the main body of the indicator.
Data type
:
16 bits binary
Range of setting value
:
0
〜
255
4
Error assistance code(4 stations ,2 stations ,1 station )
Data type
:
16 bits binary
Range of setting value
:
0
〜
255
Error code
Error support code
Error contents
0
0
No error
99
0
In case of setting the unspecified data in
command No.
1
1
In case of the instrument is “Calibration mode”,
“Check mode” and “Monitor mode”.
1
2
In case of setting the ZERO or A/Z at the
prohibition condition,
1
13
In case of the data setting other than specification
in general data area,
1
14
In case of connecting error of internal
5
General data area(4 stations ,2 stations )
When the setting value reading out command is ordered by using the general command
request (Request 2), this area displays the setting value.
Data type
:
32 bits binary with + or
−
.
Range of setting value
:−
99 999
〜
99 999
6
Command No.(Response)(4 stations ,2 stations )
When the command order is executed by the general command request (Request 2), this area
displays that command No.
Data type
:
8 bits binary
7
Operation mode (Response)(4 stations ,2 stations )
When the changeover of the operation by the operation mode changeover request (Request 3),
this area displays the mode.
Data type
:
8 bits binary
8
Indicate value(NET weight/ GROSS weight) (2 stations ,1 station )
It is area which showing the GROSS weight value or NET weight value.
Data type
:
32 bits binary with + or
−
Range of setting value
:−
99 999
〜
99 999