background image

 

VI 

History of revision 

Date 

Instruction manual No. 

Details of revised point 

Jun. 2003 

DRW. NO.EN294-1170 

First Version 

Oct. 2003 

DRW. NO.EN294-1170-A 

ECN FN03

02108 

Correction

 

5

2.Chang of GAIN set value 

Jun.2005 DRW. 

NO.EN294-1170-B 

ECN FN05

02055 

Correction

 

1.For maintenance of fan motor 
3

2.For analog output when stator is connected 

4.For output polarity of torque meter 
6.For voltage output and current output 

Feb. 2010 

DRW.No.EN294-1170-C 

ECN FN10

02026 

 Change 

 

Front cover’s logo is changed. 

Oct. 2010 

DRW.No.EN294-1170-D 

ECN FN10

02140 

 Change 

 

Minebea logo is changed. 

Feb. 2012 

DRW.No.EN294-1170-E 

ECN FN11

02191A 

 Add 

 

1

(4)    Maintenance of dust filter 

6      <for maintenance of dust filter> 
7

4   Add ’Dust filter’ 

10

2    Exchange method of dust filter 

 Change 

 

10

1    Figure of exchange method of fuse 

Feb. 2018 

DRW.No.EN294-1170-F 

Due to ECN FN17-02017 

Delete the company name in the cover page. 

Delete the company name in the contents. 

 
 

Summary of Contents for CSA-562B

Page 1: ...Transmitter for Torque transducer CSA 562B Instruction Manual EN294 1170 F ...

Page 2: ......

Page 3: ...ains installation procedures and connecting method and also operating method for the Transmitter CSA 562B for torque transducer Make use of it properly after reading through the manual carefully Be sure to deliver the manual to the end user Moreover the end user should keep the manual at hand after reading it over ...

Page 4: ...t do this Take care and For reference Be sure to read these items where these marks are attached Warning Warning may cause injury or accident that may harm to the operator Do not do these things described here Caution during operation and working Be sure to read the item to prevent malfunction Mark during operation Press the switch ...

Page 5: ...gh temperature area D Do not use the instrument in a high humid area D Do not install the instrument where there are vibrations and shocks D Do not use the instrument where there is excess of dusts and fine particles D Do not use the instrument where there are corrosive gas and salt and like that D Do not install the instrument where there is rapid change of temperature and humidity D Do not insta...

Page 6: ...ounting are as follows Outline dimensions Frong Side Panel cut size for example Rear Front Inside 40 194 5 5 66 160 209 2 5 68 175 40 14 9 5 194 172 20 260 φ5 5 Unit mm Warning Please note the forllowing points to prevent any troublesome or any electrical shock when you set up the instrument D The tolerance of the power supply voltage and the frequency is AC85 V to AC132 V 50 60 Hz D Please confir...

Page 7: ...ecute the maintenance of fan motor once a year 4 Maintenance of dust filter This device has a structure to attach a dust filter to the inlet of the fan motor At least once a year is encouraged to replace a dust filter Warning Please do not continue to use the dirty dust filter May cause unexpected failures ...

Page 8: ... torque meter 6 For voltage output and current output Feb 2010 DRW No EN294 1170 C ECN FN10 02026 Change Front cover s logo is changed Oct 2010 DRW No EN294 1170 D ECN FN10 02140 Change Minebea logo is changed Feb 2012 DRW No EN294 1170 E ECN FN11 02191A Add 1 4 Maintenance of dust filter 6 for maintenance of dust filter 7 4 Add Dust filter 10 2 Exchange method of dust filter Change 10 1 Figure of...

Page 9: ...ethod 8 4 1 Calibration method of torque 8 4 2 Preparation before adjustment 8 4 3 Electrical calibration 8 4 4 Calibration by actual torque 9 5 Analog output 10 5 1 Voltage output 10 5 2 Current output option 10 5 3 Filter 11 6 Trouble shooting 12 6 1 Execute the trouble shooting 12 7 Specifications 17 7 1 Specifications 17 7 2 General specifications 17 7 3 Standard specifications at the shipment...

Page 10: ......

Page 11: ...al display monitor 4 1 2 digit of digital display is adopted for voltage output monitor and 1 mV monitoring is available 2 Name and function of each point 2 1 Front panel 1 2 3 4 6 7 8 9 10 5 1 Monitor Displays the output voltage digitally Minimum digit is 1 mV 2 ZERO trimmer For initial balance adjustment 3 SPAN trimmer For sensitivity adjustment ...

Page 12: ...e for the current output 9 GAIN switch of the current output Applied with the optional current output Use for the set of sensitivity in current output 10 Adjustment switch of the current output Applied with the optional current output Use for change of condition in current output 2 2 Rear panel 1 2 3 4 1 INPUT connector Connect with stator 2 OUTPUT connector Connector for voltage output current ou...

Page 13: ...Connection with stator CSA 562B Stator P N of connector plug CSA 562B SRCN6A16 10P JAE Stator TC1108 12A16 14M 11 8 Tajimi musen Please use the cable attached with torque transducer in connecting the instrument with stator And don t extend the cable by using the terminals because it will cause Moreover please do not extend the cable with a terminal block etc because it is easily influenced by the ...

Page 14: ...10S JAE 2 Connection of voltage output V to D V M or sequencer Red Red White 3 Connection of current outptu Option Black A to D V M or sequencer Black White As for standard unit the electric current output is not adjusted Execute the adjustment of current output after completing the adjustment of voltage output When the procedure is made oppositely the adjusting condition of current output changes...

Page 15: ...2 2 kΩ 2 2 kΩ to inside The length of attached output cable is 2 m 5 ALARM output 1 Operation It is output outside that normal operation became impossible as ALARM signal when the rotor and stator is not set up at the appropriate position or when the light part of an optical receiving in the status part becomes dirty It is the same operation as ALARM LED of a front panel 2 Equivalent circuit of ou...

Page 16: ...onsumption 145 VA at maximum at AC100 V AC85 V to AC135 V D class single earth Warning Connections with the power supply and the earth should be made securely according to the figures and also within the rated capacity of the instrument If neglected it may cause an unexpected cause of failure Grounding should be the D class with single earth If neglected it may cause an unexpected malfunction due ...

Page 17: ...he environment that moisture adheres to this instrument Moreover please never pour water directly 2 Connection D The connecting cable with the torque transducer must use the cable attached to the torque transducer D Please separate the cable connected with this instrument as long as possible from the noise sourse like a power supply line motor and inverter or I O line for control etc It causes the...

Page 18: ...itial torque Adjust the voltage output to 0 000 V or the current output option to 12 00 mA by turning the ZERO trimmer When the voltage output is used together with the current output option the voltage output is previously adjusted and then the current output option is adjusted SPAN trimmer for voltage output 3 Span adjustment The output voltage is matched by using SPAN trimmer to become the CHEC...

Page 19: ...pply the rated torque on the torque transducer Adjust the voltage output to 10 000 V by using the SPAN trimmer When the voltage output is used together with the current output option adjust the voltage output previously and then adjust the current output option SPAN trimmer ZERO trimmer 4 Re adjustment of ZERO point Make the torque transducer to no load condition and proceed the step 2 again to ad...

Page 20: ...i When the output of 12 00 mA 8 00 mA at 0 rated output of torque The current output adjustment switch SW402 is set to the upper part ii When the output of 4 00 mA 20 00 mA at 0 rated output of torque The current output adjustment switch SW402 is set to the lower part The main setting of the voltage output and the current output is as follows a When 12 mA of the current output at 0 V of the voltag...

Page 21: ...e cut off frequency of the low pass filter can be set with FILTER set switch FILTER Cut off frequency 0 1 Hz 1 10 Hz 2 30 Hz 3 50 Hz 4 100 Hz 5 300 Hz 6 500 Hz 7 1 kHz 8 9 Don t set to 8 and 9 of the FILTER set switch ...

Page 22: ... very carefully since the confirmation in the condition to supply the power has the possibilities such as electrical shocks and leaks OK NG Supply power again Operation Abnormal operation Execute the trouble shooting Normal Operation Start measurement 6 1 Execute the trouble shooting 1 2 YES YES YES NO NO NO Voltage output is not made Voltage output is varies Execute the trouble shooting 3 Display...

Page 23: ...tents of failure and situation at site in details YES YES YES NO NO NO 4 Supply the power as specified Exchange the fuse as per the paragraph 10 1 Execute the repair of the power cable Inform us about the contents of failure and situation at site in details Specification of power supply is different Fuse is cut off Power cable is cut off ...

Page 24: ...tive of the input cable YES YES YES NO NO NO The position match of the rotor and stator cannot be done 6 Execute the repair or exchange the torque transducer Set the correct position refering to the instruction manual of torque transducer Cut off and shorten of the input cable wire 5 YES NO Remove the LED protection cover Forget to remove LED protect cover of torque transducer rotor section Inform...

Page 25: ...sing the insulating material electrically For maintenance of fan motor When this product is used under the environment of the oil mist there is a thing which fan motor stops because of oil and dust A serious problem which leads to the breakdown occurs if fan motor stops Please execute the maintenance of fan motor once a year For the voltage output and current output Connecting of the instrument wi...

Page 26: ...ilter Contamination of the dust filter lower the internal cooling capacity voltage output and current output fluctuations caused which may cause other serious problems At least once a year is encouraged to replace the dust filter ...

Page 27: ...dB Display section Display of output voltage 0 to 10 000 digital display Green LED Sampling Approx 4 times s Remote function CHECK ALARM function ALARM output 7 2 General specifications Operating temperature humidity range 0 to 40 85 RH or less Non condensing Power supply Power supply voltage AC85 V to AC132 V Power supply frequency 50 60 Hz Power consumption Approx 100 VA at AC100 V Insulation re...

Page 28: ...ide Panel cut size Rear Front inside 40 194 5 5 66 160 209 2 5 68 175 40 14 9 5 194 172 20 260 φ5 5 Unit mm 8 Options 8 1 Current output P N CSA562B P07 Output 4 mA to 20 mA Load resistance 510 Ω or less Non linearity 0 05 F S or less ...

Page 29: ...agent from which you have purchased 9 2 Repair Before asking repairs make checks once again that the connection setting and adjustment for the instrument have finished properly by referring to 6 Trouble shooting Especially make checks whether the connections of sensors are disconnected or cut off After that still there may be found some defects in the instrument contact us sales office or sales ag...

Page 30: ...ate it causes and unexpected faulty of the instrument 1 Turn OFF the power supply for the instrument 2 Remove the rear foot and panel assembly Rear foot 3 Remove the cover of the left of the front 4 Exchange the fuze installed in the power card 5 After the fuze is exchanged the cover and the panel installation rear foot are stopped with the screw ...

Page 31: ...e the dirty dust filter It may cause unexpected failures 1 Turn OFF the power supply for the instrument 2 Replace the dust filter in the groove of left cover there are no sides 3 To clean squeeze the center of the dust filter It can be easily removed by pulling outward Filter ...

Page 32: ......

Page 33: ......

Page 34: ...e Product Sales Management 1 1 1 Katase Fujisawa shi Kanagawa ken 251 8531 Japan Tel 81 466 23 2681 Fax 81 466 22 7191 Sensing Device Business Unit FUJISAWA PLANT 1 1 1 Katase Fujisawa shi Kanagawa ken 251 8531 Japan Tel 81 466 22 7151 Fax 81 466 22 1701 KARUIZAWA PLANT 4106 73 Miyota Miyota machi Kitasaku gun Nagano ken 389 0293 Japan Tel 81 267 31 1309 Fax 81 267 31 1353 HOMEPAGE ADDRESS http ww...

Reviews: