background image

NOTICE

Warning of damage to property and/or the environment.

NOTICE indicates that damage to property and/or the environment may occur if
appropriate safety measures are not observed.

Take the corresponding safety precautions.

Note:

User tips, useful information, and notes.

1.6

Hotline

Phone: +49.40.67960.444

Fax: +49.40.67960.474

eMail: [email protected]

1 Introduction

Mounting kits PR 95T/00, ../01, ../10, ../11

Minebea Intec

EN-3

Summary of Contents for PR 95T/00S

Page 1: ...01 10 11 Installation Manual Translation of the Original Installation Manual 9499 053 09500 Edition 1 1 0 10 21 2019 Minebea Intec GmbH Meiendorfer Str 205 A 22145 Hamburg Germany Phone 49 40 67960 3...

Page 2: ...fied personnel In correspondence concerning this product the type name and release number serial number as well as all license numbers relating to the product have to be cited Note This document is pa...

Page 3: ...n with integrated jack up 6 3 2 1 General instructions 6 3 2 2 Jack up with centering guide 7 3 2 3 Adjusting the built in lift off protection 8 4 Specifications 10 4 1 Equipment supplied 10 4 1 1 Mou...

Page 4: ...when measures for preventing hazards are not followed DANGER Warning of personal injury DANGER indicates death or severe irreversible personal injury which will occur if the corresponding safety meas...

Page 5: ...he environment may occur if appropriate safety measures are not observed Take the corresponding safety precautions Note User tips useful information and notes 1 6 Hotline Phone 49 40 67960 444 Fax 49...

Page 6: ...llation turning over or being shifted thus eliminating danger to people animals or goods even in the case of a break in a load cell or mounting element Installation and repair work must only be carrie...

Page 7: ...3 1 Load cell and constrainer arrangement Examples Key Do not constrain this position Constrainer Load application Possible direction of movement 3 Recommendations for installation Mounting kits PR 9...

Page 8: ...elastic constructions it may be necessary to deviate from this recommendation in order to guarantee the weighing object has sufficient stability 3 2 Internal lift off protection with integrated jack...

Page 9: ...load cell as follows 1 Turn the nut 5 until the load cell is unloaded and can be removed together with the upper load disc 2 Insert the load disc into the load cell 3 Insert the load cell into the mou...

Page 10: ...3 2 3 Adjusting the built in lift off protection 1 Turn the nut 5 downwards 2 Check that the distance A 1 2 mm Mounting kits PR 95T 00 01 10 11 3 Recommendations for installation EN 8 Minebea Intec...

Page 11: ...nut 5 upwards to loosen the nut 4 4 Turn the screw 2 upwards to configure the safety distance A 5 Re secure the nut 4 6 Turn the nut 5 downwards again 3 Recommendations for installation Mounting kits...

Page 12: ...ction with integrated jack up 2 6 Upper plate 7 Lower plate 8 Screw 2 and spring washer 2 for the potential equalization cable 9 Screw 2 10 Washer 2 11 Spacer 12 Load disc The following are not shown...

Page 13: ...Lower plate 8 Screw 2 and spring washer 2 for the potential equalization cable 9 Screw 2 10 Washer 2 11 Spacer 12 Load disc 13 Constrainer with joint head 2 screwed joint nut 2 joint pin 2 and lo ckin...

Page 14: ...4 2 Dimensions PR 95T 00S all dimensions in mm Load cell Nominal capacity A MP58T 91 2268 kg 82 4 mm MP79T 227 2268 kg 83 3 mm Mounting kits PR 95T 00 01 10 11 4 Specifications EN 12 Minebea Intec...

Page 15: ...PR 95T 01S all dimensions in mm 4 Specifications Mounting kits PR 95T 00 01 10 11 Minebea Intec EN 13...

Page 16: ...PR 95T 10S all dimensions in mm Load cell Nominal capacity A MP58T 91 2268 kg 82 4 mm MP79T 227 2268 kg 83 3 mm Mounting kits PR 95T 00 01 10 11 4 Specifications EN 14 Minebea Intec...

Page 17: ...PR 95T 11S all dimensions in mm 4 Specifications Mounting kits PR 95T 00 01 10 11 Minebea Intec EN 15...

Page 18: ...g Gross weight 4 2 kg 8 8 kg Mounting kits PR 95T 10S and PR 95T 11S PR 95T 10S PR 95T 11S Max capacity of load cell 91 2268 kg 5099 kg Permissible horizontal force max 5 kN max 20 kN Horizontal destr...

Page 19: ...kit and substructure for vibration dampening or for temperature insulation a load compensating plate must be provided between this soft filler layer and the mounting kit to ensure even load applicatio...

Page 20: ...ith the flexible copper strap provided for this purpose included in the equipment supplied see Chapter 4 1 During any additional electrical welding work near the load cell Disconnect the load cell cab...

Page 21: ...d mounting kit in the required position on the foundation substructure Always make sure that the plates are in parallel and seated vertically above each other 3 Mark mounting holes for the lower plate...

Page 22: ...12 in the upper plate 6 8 Apply sufficient grease to the contact surfaces between load cell load disc and upper plate load disc 9 Insert the load disc 12 into the load cell 14 vertically The load disc...

Page 23: ...t of the measured object due to thermal expansion vibration etc can be utilized without reducing the measuring accuracy only if the load cell and constraining unit have been installed exactly To avoid...

Page 24: ...top to bottom and around the mounting kit NOTICE Some cleaning agents may not be compatible with the mounting kit material When using cleaning agents ensure that their compatibility with the mounting...

Page 25: ...nsorted municipal waste so that it can then be recycled Before disposing of or scrapping the product any batteries should be removed and taken to a suitable collection point Please see our T Cs for fu...

Page 26: ...5312 321 28056 2 Load disc 91 2268 kg 5312 693 98158 3 Load disc 5099 kg 5312 693 98159 4 Constrainer 91 2268 kg 5312 693 98094 5 Constrainer 5099 kg 5312 693 98095 6 2 locking washer 10 mm DIN 6799...

Page 27: ......

Page 28: ...Published by Minebea Intec GmbH Meiendorfer Strasse 205 A 22145 Hamburg Germany Phone 49 40 67960 303 Email info minebea intec com www minebea intec com...

Reviews: