5.4
Check mounting
When all mounting kits have been installed, check them for proper mounting.
In particular, force shunts should be avoided.
Example: PR 95/10S
It is essential to check:
-
that the load cell has been inserted in the mounting kit without being canted.
-
whether the upper and lower plates are mounted in a horizontal position.
-
whether free moving space and the required play for thermal expansion are provided.
7.
Once all welding near and mounting work on the weighing object is complete, clean
the load cell base on the lower plate (7) and the recess for the load disc (12) in the
upper plate (6).
8. Apply sufficient grease to the contact surfaces between load cell/ load disc and upper
plate/load disc.
9. Insert the load disc (12) into the load cell (14) vertically. The load disc must not be
canted!
10. Mount the load cell (the arrow for the load direction must point downward) with the
screws (9) and the spacer (11) on the lower plate (7) so that the load disc (12) is seated
centrally in the recess in the upper plate (6). It is essential to observe the property
classes and tightening torques of the screws (9) and the property classes of the
washers (see Chapter
).
11. Turn the nut (5) slowly downward to exert a load on the load cell and position the
centering guide (3) below the upper plate (6).
Mounting kits PR 95T/00, ../01, ../10, ../11
5 Installation