1
2
3
7
6
5
8
4
Procedure:
Note:
Turn the dummy to check whether there is clearance between dummy (6) and
recess (3). If necessary, insert thin, deburred sheet-metal plates between
-
the upper plate (2) and vessel bracket/foot (1) or
-
the lower plate (7) and foundation (8).
PR 6144/54N: approx. 25 mm
PR 6144/15N: approx. 30 mm
PR 6144/35N: approx. 30 mm
PR 6144/55N: approx. 35 mm
1. Screw the upper plate (2) to the vessel bracket/vessel foot (1). The property classes
and tightening torques of the screws must be observed; see Chapter
.
2. Position the lower plate (7) with the dummy (6) on the foundation. Ensure that the
upper and lower plates are parallel and seated vertically above each other.
3. Carefully place the vessel on the lower plate so that the dummy is seated in the
recess (3) of the upper plate.
4. Fix the upper plate (2) using stops (5) (4×).
5. Fix the lower plate to the foundation. The property classes and tightening torques of
the screws must be observed; see Chapter
.
6. Connect an equipotential bonding conductor (not supplied with the mounting kit)
between the upper and the lower plates (4).
7. Release the stops and lift the vessel until the dummy can be removed:
8. Remove the dummy.
5 Installation
SeismicMount PR 6144
Minebea Intec
EN-15