Type of assembly
H
without adapter plate
35 mm
with adapter plate
75 mm
3. Lift the vessel.
4. Make the drill holes for the threaded pins/stud screws (10).
5. It is indispensable to insert the threaded pins/stud screws (10) vertically with the
required height 'H'.
6. When using PR 6041/80S adapter plates: Place adapter plate (15) on the bottom (7)
within the outline marking (9).
7. When using PR 6041/80S adapter plates: Mount the adapter plate using screws (15).
Make sure to observe the tightening torque of the nuts (13) and the property classes
of the nuts (13) and washers (14), see Chapter
.
5 Installation
Hygienic Weighing Module Contego®
Minebea Intec
EN-25