5.3.2
Mounting the weighing module
Note:
The following describes how to mount the load cell with the adapter plate PR 6041/80S
(see Chapter
The operations must be performed at all supporting points (e.g. vessel foot) of the
weighing object (e.g. vessel).
1. Check if all threaded holes required for mounting in the vessel foot/lug are provided.
2. Insert the O-ring (4) into the groove of the upper plate (3) and put the weighing
module under the vessel foot (5).
3. Slip the bellows (not shown) over the mounting kit and the vessel foot (5) carefully so
that the mounting kit remains accessible for mounting.
4. Fit the mounting kit to the vessel foot (5). Make sure to observe the tightening torque
of the screws (2) and the property classes of the screws (2) and washers (1), see
Chapter
5 Installation
Hygienic Weighing Module Contego®
Minebea Intec
EN-23