background image

be seen in all cases. If the VoIP VLAN is enabled then Control, AVB, and VoIP MAC addresses will be seen on P1. If the
VoIP VLAN is not enabled VoIP shares the same MAC address as control on P1.

TesiraFORTÉ X uses the device's AVB MAC address for LLDP and RSTP negotiations, traffic from this MAC address
will be seen on all ports in all modes.

In FW 4.1.2.9 there is a bug which will report the Dante MAC in the
media_avb_2 interface. The expected MACs seen on P1 in a
Wireshark trace will be sequential, with control using the lowest
number, media_avb_2 as the next, media_voip_3 as the next. An
example is shown here.

Network Command String block

The

Network Command String

block can be used in TesiraFORTÉ X to communicate with devices visible through either

the control port (P1) or the media ports (P2-5). When configuring the NCS block, the IP address assigned to the NCS
block

Server address

will determine which network ports the string traffic is routed to. The NCS block must use a

device address which is valid within either the control subnet or the media subnet or it will not be able to connect. The
control and media network ports must be in different subnet domains so the addresses are logically separate.
TesiraFORTÉ X will not relay a command string from the control port P1 through to P2-5, it does not function as a
control tunnel.

To control LEDs and other attributes of Dante devices connected to P2-5 an NCS block can be used to send command
strings to the device. These commands cannot be sent directly across from a control system connected to P1, as P1
does not pass traffic to P2-5. Two options are available, the control system can trigger the NCS block targeted to a
device connected to P2-5, or the control system can control TesiraFORTÉ X using the

avb_media_2

IP address on

P2-5.

Control devices

Control devices such as HD-1 and TEC-X communicate over IP with the Forte X but can be connected to and
discovered on the media ports (P2-5). They must acquire addresses in the same range as the AVB (

media_avb_2

)

interface, and these addresses must be in a different IP subnet range than the control port (P1) for proper behavior.

Firmware Update

Unconfigured or auto-configured TesiraFORTÉ X and Devio SCX devices support firmware updates via their web UI.

TesiraFORTÉ X uses the file

tesiraforte-x_fw_web_v#-#-#.tfa

for releases 4.1.2 and later. (Firmware releases 4.1.1

and earlier updates for

both

device types used the

Devio SCX Firmware #.#.#.tfa

file.) The

tfa

is a smaller file specific to

these hardware devices, allowing stable updates via the web interface.

The TesiraFORTÉ X and Devio SCX firmware can also be updated via Tesira software using the same

Tesira

https://support.biamp.com/Tesira/Miscellaneous/TesiraFORTE_X

Updated: Tue, 07 Dec 2021 16:46:18 GMT

Powered by

8

Summary of Contents for TesiraFORTE X 1600

Page 1: ...conference rooms but TesiraFORTÉ X can also be custom programmed for many other applications TesiraFORTÉ X offers installers two discrete modes of operation The default behavior allows single button press auto configuration assisted by Biamp Launch The second option allows users to manually configure and completely customize the device signal paths a la a traditional Tesira DSP device TesiraFORTÉ ...

Page 2: ...uto configuration process a report card detailing the room s acoustic performance before and after optimization plus the Biamp hardware manifest is available for viewing via a web browser and can be printed as a pdf Auto configuration is a closed system which allows a consistent and repeatable installation process for many conference room applications Auto configuration is initiated using the Biam...

Page 3: ...of AVB between Biamp Tesira devices 32x32 audio channels on 32x32 flows of Dante 2 analog mic line inputs with phantom power 2 analog mic line outputs and 4 ports of GPIO Note that some hardware functions are only available when TesiraFORTÉ X is manually configured Prior to running Launch configuration TesiraFORTÉ X will display a Device ID of 0 indicating it is unconfigured To manually configure ...

Page 4: ...ons GPIO connections and support for Dante audio when manually configured Launch configured TesiraFORTÉ X devices do not use the analog I O Dante or GPIO These features become available when manually programmed Neither TesiraFORTÉ X nor Devio SCX can have a Launch file extracted from the device It is a closed system Launch tuning results are shown in the device s Report Card Network Connectivity T...

Page 5: ...ble via the control and VoIP interface port via the control IP address found with the Biamp Discovery app Biamp Tesira software version 4 0 and higher or Biamp SageVue management software Password changes persist through device resets via Device Maintenance Clear Configuration and pinhole resets VoIP settings also persist through device resets via Device Maintenance Clear Configuration or configur...

Page 6: ...hese 4 ports also support PoE for peripheral devices Port rules are automatically managed across ports 2 5 When connected to another Biamp network appliance such as TC 5 TC 5D or another TesiraFORTÉ X both AVB and Dante traffic are allowed to pass across the port If MSRP packets are detected from a connected port indicating a connected AVB switch or endpoint then the port becomes 802 1as capable i...

Page 7: ...y may not be deemed sufficiently hardened to meet network security requirements in the most rigorous applications If a site requires hard separation between port functions such as a guarantee that a VoIP interface is 100 isolated in all conditions then either a Tesira Server IO with VoIP 2 or a TesiraFORTÉ VT with their dedicated hardware isolated VoIP cards are the appropriate solution MAC Addres...

Page 8: ...ough to P2 5 it does not function as a control tunnel To control LEDs and other attributes of Dante devices connected to P2 5 an NCS block can be used to send command strings to the device These commands cannot be sent directly across from a control system connected to P1 as P1 does not pass traffic to P2 5 Two options are available the control system can trigger the NCS block targeted to a device...

Page 9: ...Audio transport between TesiraFORTÉ X and other Tesira devices in the same system is done via implicit AVB With implicit AVB there is no need to manually define AVB paths the Tesira compiler will automatically determine the path and establish the required AVB streams between devices TesiraFORTÉ X does not support explicit AVB however other Tesira Server class AVB devices in the same system can sup...

Page 10: ...C 5 can be used to add Dante capable ports to a TesiraFORTÉ X always connect P1 of the TC 5 to P2 5 of TesiraFORTÉ X A TC 5D is not needed The Dante interface is hosted in the TesiraFORTÉ X Dante discovery does not pass across the TesiraFORTÉ X between port 1 and ports 2 5 To manage connected Dante endpoints a PC running Dante Controller can be attached either directly to the TesiraFORTÉ X on port...

Page 11: ...hanced security features as well as support for other new VoIP features including the Opus audio codec Forte X no longer supports the G 723 codec TesiraFORTÉ X VoIP supports 1 line with 2 call instances VoIP X supports all current Tesira VoIP vendors except Skype for Business The HD 1 dialer is compatible with TesiraFORTÉ X and can be connected via ports 2 5 In Launch configured systems the HD 1 i...

Page 12: ...atible TLS version A TFTP server is able to be configured in the VoIP endpoint either statically or via DHCP option 66 or a custom option VoIP X supports the TFTP server address as either dotted quads or FQDN The use of a VoIP VLAN 802 1Q is optional If a VLAN is configured ingress traffic with an unmatched VLAN tag shall be discarded If a VLAN is configured all egress traffic will be tagged The V...

Page 13: ...the same as seen on ports 13 16 of the Tesira EX Logic box and the GPIO ports on other Tesira Server class devices TesiraFORTÉ X uses a female 6 pole 3 81mm pitch block connector for the GPIO connection Installation Mounting TesiraFORTÉ X comes with a pre attached wall mount and drywall anchors to allow placement behind wall mounted displays The wall mount features an integrated cable management c...

Page 14: ...412 ft2 12 18 people o MRB L X400 C Ceiling mic TesiraFORTÉ X 400 1 TCM XA 1 TCM XEX and 2 pair of C IC6 plus cables o MRB L X400 T Table mic TesiraFORTÉ X 400 1 AMP 450BP 1 TTM X 1 TTM XEX and 2 pair of C IC6 plus cables Block family A new TesiraFORTÉ X block family is available in Tesira software version 4 0 and higher TesiraFORTÉ X devices allow the selection of 4 8 or 16 channels of AEC when t...

Page 15: ... configure the VoIP block while offline a popup message will remind them of the behavior Dante is supported on all manually configured TesiraFORTÉ X devices This includes support for AES67 through the Dante interface Dante I O blocks can be manually added as desired they are not placed into a layout with TesiraFORTÉ X by default The Dante interface shares an IP address with the AVB interface on Te...

Page 16: ...ecommended number of units users will need to consider the position of each device in the network topology when applying firmware updates to ensure all devices can receive the update without being blocked by a mid span device updating simultaneously This scenario may require manually selecting a sub set of devices for their firmware update then manually selecting a second group once the first has ...

Page 17: ... unknown we assume the worst case scenario of 200µs across all network hops Eight network switches at 200µs each plus two endpoints at 125µs each totals 1850µs leaving 150µs to spare A daisy chained system with 10 network devices requires 9 connecting links or hops This is how we determine the 9 hop maximum diameter A network comprised only of devices with a 125µs pass through latency would allow ...

Page 18: ...that should always guarantee robust operation https support biamp com Tesira Miscellaneous TesiraFORTE_X Updated Tue 07 Dec 2021 16 46 18 GMT Powered by 18 ...

Reviews: