required AVB streams between devices. TesiraFORTÉ X does not support explicit AVB endpoints, however, other
Tesira Server-class AVB devices in the same system can support explicit AVB endpoints and audio can be routed to
and from any processing device in the system in this manner.
The USB X interface allows 1x1 or 2x2 configuration and a choice of line in and line out or speakerphone behavior with
AEC in the audio DSP or AEC in the PC. The speakerphone options allow Tesira to set a flag for the connected USB
host to indicate a preference for AEC on the Tesira device or AEC in the UC application. Not all UC platforms offer
support for this option and will simply ignore this choice.
The USB X interface supports HID mute sync for use with UC platforms.
The VoIP X Control/Status block is not available for
configuration while offline. Unlike other Tesira VoIP
devices, TesiraFORTÉ X VoIP is entirely software based
and is configured solely via an
internally served web
page
. The web page can be launched by double-clicking
on the Control/Status block in Tesira SW or connecting to
the device directly via its IP address and choosing the
VoIP pages. If users attempt to configure the VoIP block
while offline a popup message will remind them of the
behavior.
Dante is supported on all manually configured
TesiraFORTÉ X devices. This includes support for
AES67 through the Dante interface. Dante I/O blocks can
be manually added as desired, they are not placed into a
layout with TesiraFORTÉ X by default.
The Dante interface shares an IP address with the AVB interface on TesiraFORTÉ X, in most applications this is not a
hindrance to implementing desired network topologies. There may be special conditions with specific user-defined
network restrictions where a desired network topology is simply not possible due to IP address rules.
are available using the Logic Input, Logic Output, and Control Voltage blocks, as with other Tesira
devices.
3rd-party control systems
Control systems can communicate with manually-configured TesiraFORTÉ X either on P1 using the TesiraFORTÉ X's
control
IP address, or on P2-5 using the TesiraFORTÉ X's
media_avb_2
(AVB/Dante) IP address.
TesiraFORTÉ X will not relay a command string from the control port P1 through to P2-5; it does not function as a
control tunnel. TesiraFORTÉ X's control and media IP addresses must be in unique logical subnets or the device will not
function properly.
https://support.biamp.com/Tesira/Miscellaneous/TesiraFORTE_X
Updated: Tue, 07 Dec 2021 16:46:18 GMT
Powered by
15