Minco TT211 Installation And Operating Instructions Manual Download Page 10

 

 

 

Minco 

Tel: 763. 571.3121 • Fax: 763. 571.0927 •  www.minco.com • Doc. #1116290(D) 

10 

Warranty

 

Items returned within one year from the date of sale, transportation prepaid, which Minco Products, Inc. (The 
"Seller") reasonably determines to be faulty by reason of defective materials or faulty workmanship will be 
replaced or repaired at the Seller's discretion, free of charge. 
 
This remedy is to be the sole and exclusive remedy available to the buyer in the event of a breach by the Seller.  
Items that show evidence of mishandling or misapplication may be returned by the Seller at the customer's 
expense. 
 
Furthermore, the Seller is not to be held responsible for consequential damages caused by its product except as 
required under Minnesota Statutes, Section 336.1-719 (3). 
 
This warranty is expressly in lieu of any other expressed warranty or implied warranty of merchantability or fitness 
for a particular purpose, and of any other obligations or liability on the part of the Seller or its employees or 
agents. 

 

Specifications 

Input: 

100 

 or 1000 

 platinum 2-lead RTD. 

Output: 

4 to 20 mA DC over specified range.

 

Accuracy: 

+/- 0.1% of span. 

Linearity: 

+/- 0.1% of span. 

Adjustments: 

Zero and Span, +/- 5% of span. 

Ambient Temperature: 

Operating:  -25 to 85 °C ( -13 to 185 °F ). 
Storage:  -55 to 100 °C ( -67 to 212 °F ). 

Ambient Temperature 

Effects: 

+/- 0.007% of span/°F (+/- 0.013% of span/°C). 
+/- 0.014% of span/°F for spans less than 20 

Warmup Drift: 

+/- 0.1% of span max., assuming  Vsupply = 24 VDC and Rloop = 250 
ohms.  Stable  within 30 minutes. 

Supply Voltage: 

8.5 to 35 volts DC with no load.  Reverse polarity protected. 

Voltage effect: 

+/- 0.001% of span per volt. 

Maximum Load 

Resistance: 

The maximum allowable resistance of the signal-carrying loop is given 
by this formula:  Rloop max = (Vsupply-10)/.02 amps. 

Maximum Output 

Current: 

27 mA. 

Connections: 

Terminal blocks for wires from AWG 22 to AWG 14. 

Physical: 

Epoxy potted for moisture resistance. 

Weight: 

1.1 oz. (30 grams). 

 
 

 
 
 
 
 
 

Summary of Contents for TT211

Page 1: ...Tel 763 571 3121 Fax 763 571 0927 www minco com Doc 1116290 D TT211 and TT711 2 Wire Temperature Transmitter Installation and Operating Instructions TT211 TT711 INTRINSICALLY SAFE NON INCENDIVE...

Page 2: ...tion Installation If installing the Temptran in a hazardous location the installer must adhere to installation requirements as set forth by the National Electrical Code NEC and any other applicable co...

Page 3: ...erature sensor or thermocouple 3 If installing in a Class I Division 2 hazardous area then the transmitters must be mounted in a vent free enclosure meeting the Electrical Utilization Enclosure Requir...

Page 4: ...parts and wiring and external cord and cable assembly strain relief shall comply with the following tests for mechanical strength a Impact Tests The equipment shall be held firmly against a rigid supp...

Page 5: ...nd D hazardous locations Models Models Models TT210 TT211 TT176 TT216 TT676 TT710 TT711 TT190 TT230 TT220 TT221 TT720 Vmax 35 volts Vmax 35 volts Vmax 35 volts Imax 150 Ma Imax 150 mA Imax 150 mA Ci 0...

Page 6: ...ion must be in accordance with the barrier manufacturers instructions ANSI ISA RP12 6 and the National Electrical Code ANSI NFPA 70 6 Control room equipment connected to the associated apparatus must...

Page 7: ...10 TT711 TT720 FOR USE IN CLASS I DIVISION 1 GROUPS A B C D HAZARDOUS LOCATIONS BARRIER BARRIER MANUFACTURER MODEL MTL 702 MANASSAS VA 706 703 361 0111 787S 788 2441 3041 3046B 4041 R STAHL 9001 01 28...

Page 8: ...TT210 TT211 TT710 OR TT711 BROWN RED BLACK ORANGE SIMPLE APPARATUS ASSOCIATED APPARATUS MODELS TT176 TT190 TT216 TT230 OR TT676 SIMPLE APPARATUS ASSOCIATED APPARATUS MODELS TT220 TT221 OR TT720 NON HA...

Page 9: ...least 01 ohms to the input of the transmitter If unsure or concerned about the decade box s accuracy measure the zero and span resistance setting using a known accurate ohmmeter and record decade box...

Page 10: ...warranty of merchantability or fitness for a particular purpose and of any other obligations or liability on the part of the Seller or its employees or agents Specifications Input 100 or 1000 platinum...

Page 11: ...C C Temperature Range Use one of the over 175 range codes in the MINCO Temptran sales bulletin Note A range that is available for a particular Temptran model is not automatically available for the TT2...