14
Installation
Voltage signal follower (PCM2x000A)
Figure 6. PCM2x000A Voltage Follower Connections
Warning
Before applying power, ensure that SO501 is set to SIGNAL
as shown in Figure 6.
Instead of using a speed adjust potentiometer, the drive may be
wired to follow a 0–10 VDC grounded or ungrounded voltage
signal. Connect the signal input (+) to POS. Connect the signal
common (–) to NEG. A potentiometer can be used to scale the
analog input voltage.
SO501
CONTROL
SELECT
JUMPER
250-0090-rev5.qxd 3/9/01 10:25 AM Page 14