- 2.22 -
STEP
1.
The device enters the LOCAL mode.
Press the [REMOTE] key and put the device back into the
LOCAL mode.
2.
Press the [TEST&CLEANING] key.
3.
Press the [ENTER] key.
The device plots the test pattern.
4.
Check the test patterns.
If a failure occurs, proceed with step 5; otherwise, terminate
the operation.
5.
Press the [TEST&CLEANING] key twice.
6.
Select the type of cleaning by pressing the
JOG keys [ ] and [ ].
soft
:
Select this if there is any missing line.
normal
:
Select this if any line is bent.
strong
:
Select this if inferior plotting cannot be
recovered after [normal] or [soft] cleaning.
7.
Press the [ENTER] key.
Cleaning starts.
The operation status is displayed as * in the second line.
8.
The device revert the LOCAL mode.
9.
Repeat steps 2, and check the result of the test
plotting.
Repeat steps 2 to 7 until normal plotting result is obtained.
< LOCAL >
width : 1272 mm
TEST DRAW
< ENT >
∗
∗
TEST DRAW
∗
∗
< LOCAL >
width : 1272 mm
TEST &
CLEANING
CLEANING
TYPE
: normal
CLEANING
TYPE
: normal
CLEANING
TYPE
: soft
CLEANING
TYPE
: strong
CLEANING
ACTIVE
∗
∗
∗
∗
∗
−
−
−
−
−
−
−
−
−
−
−
< LOCAL >
width : 1272 mm
TEST &
CLEANING
Summary of Contents for JV3-130 SP II