Sample C
The point from which the cutter starts is this side (or far side) of the predetermined start position.
Corrective measure
Adjust the set value for the [START
CORRECTION] in [CUTTING CONDI-
TIONS] using the cutting condition set-
ting functions. (See page 2.28.)
Adjust the pattern A for the “adjustment
of the eccentricity” using the tool adjust-
ing functions. (See page 3.6.)
Sample D
The point at which the cutter finishes cutting goes beyond (or does not reach) the predetermined end
position.
Corrective measure
Adjust the set value for the [END COR-
RECTION] in [CUTTING CONDI-
TIONS] using the cutting condition set-
ting functions. (See page 2.28.)
Adjust the pattern A for the “adjustment
of the eccentricity” using the tool adjust-
ing functions. (See page 3.6.)
Sample E
The tangential cutter shifts to the right from the correct position in terms of the advancing direction.
Corrective measure
Adjust the pattern A for the “adjustment
of the eccentricity” using the tool adjust-
ing functions. (See page 3.6.)