— 1.7 —
Right-hand side face of the electrical box
Blower unit
Name
Function
1
Power switch
Used to turn on/off the power to the blower unit. Normally, it is set to the
on position. Turn it off when conducting maintenance works.
2
Signal wire connector
To be connected, using a signal wire, to the signal wire connector for the
blower on the electrical box.
3
Power connector
The power cable for the blower is connected to this connector.
Name
Function
1
Power connector
To be connected to the power cable of the plotter.
2
Main power switch
Used to turn on/off the main power of this device. Normally set it to the on
state. Set it to the off state when conducting maintenance works.
3
Foot switch connector
Foot switch for vacuum is connected to this connector. (Optional)
Note: The shape of this connector may differ from that shown in the photograph.
4
RS-232C interface
To be connected to a personal computer using an interface cable.
5
IC card slot
To be used when conducting maintenance works.
6
Signal wire connector for
To be connected to the blower unit using a signal wire.
blower
7
Optional connector
An optional device is connected to this connector.
1
2
3
4
5
6
7
1
2
3
• When using a separately sold
blower that differs from the stan-
dard blower, there may be no
power switch. For the output
voltage, refer to the value display
on the blower unit.
Summary of Contents for CF-0907
Page 16: ......
Page 48: ......
Page 68: ......
Page 84: ......
Page 96: ......
Page 100: ...2 52...
Page 122: ......
Page 140: ......
Page 158: ...A 10...
Page 159: ...A 11 C OUTPUT SAMPLES Cutting quality 1 Cutting quality 2...
Page 160: ...A 12 ASCII dump list Sample coated...
Page 161: ...A 13 Sample E corrugated Sample B corrugated...
Page 162: ...A 14 Circle cutting R 3 5 10 20 50 100 Parameter dump list R 3 R 5 R 10 R 20 R 50 R 100...
Page 168: ...A 20...
Page 169: ......
Page 170: ...D200962 1 30 12032004 MIMAKI ENGINEERING CO LTD 2004...