— A.17 —
E. MAINTENANCE
To use the device comfortably for an extended period of time, it is recommended to perform peri-
odical cleaning.
• Use neither detergent containing abrasives nor thinner. Such materials can deform
the cover and the cutting panel.
Cutting panel surface
If any of the suction holes on the cutting panel is clogged, be sure to insert a thin wire into the
clogged hole. The substance clogged in the hole will be discharged from the exhaust port of the
blower.
If the cutting panel surface is slightly stained, clear stains with a piece of clean and dry cloth. If the
cutting panel surface is heavily stained, impregnate a piece of clean and dry cloth with a little
amount of alcohol and wipe the stained surface.
Unit B
The axis vibrating reciprocally may stop vibrating due to insufficient lubrication.
Before starting operation, wipe the axis with a clean and dry cloth. Then, using a brush, apply a
small amount of the supplied grease to the axis.
Cover
If the cover is slightly stained, clear stains with a piece of clean and dry cloth. If the cover is heavily
stained, impregnate a piece of clean and dry cloth with a little amount of alcohol and wipe the
stained surface.
Apply grease to this axis.
Summary of Contents for CF-0907
Page 16: ......
Page 48: ......
Page 68: ......
Page 84: ......
Page 96: ......
Page 100: ...2 52...
Page 122: ......
Page 140: ......
Page 158: ...A 10...
Page 159: ...A 11 C OUTPUT SAMPLES Cutting quality 1 Cutting quality 2...
Page 160: ...A 12 ASCII dump list Sample coated...
Page 161: ...A 13 Sample E corrugated Sample B corrugated...
Page 162: ...A 14 Circle cutting R 3 5 10 20 50 100 Parameter dump list R 3 R 5 R 10 R 20 R 50 R 100...
Page 168: ...A 20...
Page 169: ......
Page 170: ...D200962 1 30 12032004 MIMAKI ENGINEERING CO LTD 2004...