Place the drain cleaner at a distance no greater 

cleaner cannot be placed within 610mm from the 

drain opening, the drain opening will need to be 

 

Greater distances can cause control problems leading 

to twisting, kinking, breaking or whipping of the cable.

‡

 

One person must control both the trigger switch 

and cable. 

If the tool stops rotating, the user must be 

able to turn the tool off to prevent twisting, kinking, 

breaking or whipping of the cable.

‡

 

Do not operate the drain cleaner in reverse rotation 

except as described in this manual.

 Running the tool 

in reverse for extended periods can cause damage to 

the cable and accessories.

‡

 

WARNING

-

jury, and product damage due to a 

short circuit, never immerse your tool, battery pack or 

certain industrial chemicals, and bleach or bleach 

containing products, etc., can cause a short circuit.

‡

 

Maintain labels and nameplates. 

These carry im-

portant information. If unreadable or missing, contact 

MILWAUKEE 

  service facility for a replacement.

‡

 

WARNING

Some dust created by power sanding, 

sawing, grinding, drilling, and other 

construction activities contains chemicals known to 

cause cancer, birth defects or other reproductive harm. 

Some examples of these chemicals are:

‡

 lead from lead-based paint

‡

 crystalline silica from bricks and cement and other 

masonry products, and

‡

 arsenic and chromium from chemically-treated lumber.

 Your risk from these exposures varies, depending on 

how often you do this type of work. To reduce your 

exposure to these chemicals: work in a well ventilated 

area, and work with approved safety equipment, such 

as those dust masks that are specially designed to 

SPECIFICATIONS

Cat. No. ...............................................M18 FFSDC16

Volts ...................................................................18  DC

No Load RPM ........................................................250

Battery Type ..................................................... M18™

Charger Type .................................................... M18™

Drain Line Capacity..................................Up to 30.5m

Cable Range..........................8mm-16mm (5/16"-5/8")
Tool Weight (With Battery)..................................7.8kg

 

SYMBOLOGY

 

  

Volts

V

 Direct 

Current

 

  No-Load Revolutions per Minute (RPM)

 

 

Do not allow battery to contact corrosive 

 

 

 

 

 

 

 

 

Only wear leather gloves

 

 

Do not transport this tool when the

 

drum and backpack are connected

-

tacts eyes, additionally seek medical help. 

Liquid 

ejected from the battery may cause irritation or burns.

‡

 Do not use a battery pack or tool that is damaged or 

risk of injury.

‡

 

-

cessive temperature. 

above 130°C (265°F) may cause explosion.

‡

 Follow all charging instructions and do not charge 

the battery pack or tool outside the temperature 

Charging im-

SERVICE

‡

 

person using only identical replacement parts. 

This will ensure that the safety of the power tool is 

maintained.

‡

 Never service damaged battery packs. 

Service of 

battery packs should only be performed by the manu-

facturer or authorised service providers.

SPECIFIC SAFETY RULES

‡

 

Only grasp the rotating cable with gloves recom-

mended by the manufacturer. 

gloves or rags can become wrapped around the cable 

and may result in serious personal injury.

‡

 

Do not allow the cutter to stop turning while the 

cable is turning. 

This can overstress the cable and 

may cause twisting, kinking or breaking of the cable 

and may result in serious personal injury.

‡

 

Use latex or rubber gloves inside the gloves rec-

ommended by the manufacturer, goggles, face 

shields, protective clothing, and respirator when 

chemicals, bacteria or other toxic or infectious sub-

stances are suspected to be in a drain line. 

Drains 

may contain chemicals, bacteria and other substances 

that may cause burns, be toxic or infectious or may 

result in other serious personal injury.

‡

 

Practice good hygiene. Do not eat or smoke while 

handling or operating the tool. After handling or 

operating drain cleaning equipment, use hot, soapy 

water to wash hands and other body parts exposed 

to drain contents. 

This will help reduce the risk of health 

hazards due to exposure to toxic or infectious material.

‡

 

Only use the drain cleaner for the recommended 

drain sizes. 

Using the wrong size drain cleaner can 

lead to twisting, kinking or breaking of the cable and 

may result in personal injury.

‡

 

Inspect cable for wear and damage before use.

 

Replace a worn or damaged cable before using the 

drain cleaner.

‡

 

Do not twist, kink or over bend cables.

 Breaking of 

the cable may result in serious personal injury.

‡

 

Inspect the drain to be cleaned before use.

 If pos-

sible, determine the access point(s) to the drain, the 

size(s) and length(s) of the drain, distance to mainlines, 

the nature of the blockage, presence of drain clean-

ing chemicals or other chemicals, etc. If chemicals 

are present in the drain, it is important to understand 

those chemicals. Contact the chemical manufacturer 

for required information.

‡

 

If needed, place protective covers in the work area.

 

The drain cleaning process can be messy.

‡

 

Make sure cable is fully retracted inside of the drain 

cleaner.

 This will prevent whipping at start up.

than 610mm from drain opening. If the drain 

®

n

o

xxxxmin.

-1

Regulatory Compliance mark (RCM). 

This product meets applicable  

regulatory requirements.

Summary of Contents for M18 FFSDC16

Page 1: ...Cat No M18 FFSDC16 M18 FUEL SWITCH PACK SECTIONAL DRUM SYSTEM OPERATOR S MANUAL To reduce the risk of injury user must read and understand operator s manual WARNING...

Page 2: ...and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose clothing or jewelry Keep your hair and clothing away from moving parts...

Page 3: ...k or tool outside the temperature Charging im SERVICE person using only identical replacement parts This will ensure that the safety of the power tool is maintained Never service damaged battery packs...

Page 4: ...able tip may be sharp Remove the cable for cleaning after each use Differ ent size and types of cables are available for different applications FUNCTIONAL DESCRIPTION 1 2 1 Handle 2 Inner drum 3 Cable...

Page 5: ...o not allow battery to contact To reduce the risk of injury wear safety goggles or glasses with side shields Always wear leather gloves Using Forward Off Reverse Switch 1 For forward clockwise rotatio...

Page 6: ...nment or binding of moving parts breakage of parts or any other condition that may affect the tool operation Return the tool battery pack and charger to a MILWAUKEE service facility for repair After s...

Page 7: ......

Page 8: ...lly Made in China for Milwaukee Tool Australia Milwaukee Tool New Zealand Printed in China WARRANTY AUSTRALIA and NEW ZEALAND SERVICE AUSTRALIA and NEW ZEALAND MILWAUKEE prides itself in producing a p...

Reviews: